11
flow, the pump is cooled by the water. Always make sure that the pump works against
as little resistance as possible. If the flow is reduced (for example, if the hose diameter
is too small, the ball valve in the line, the delivery height is too high, contamination, etc.),
the operating temperature increases significantly. Already at 55 degrees Celsius, lime
deposits on the pump motor. In the worst case, this lime layer becomes so thick that the
rotor runs very stiff, blocked and the engine burns. Damage caused by dirt and calcifi-
cation is excluded from the guarantee. The user must properly service and clean the
pump depending on the amount of dirt and lime. After cleaning, reassemble the pump in
reverse order.
Observe the relevant product videos on
cleaning and maintenance
in our Youtube channel:
https://www.youtube.com/user/FIAPGmbH
WEAR PARTS
The pump must not run dry. Dry running leads to rapid wear and damages the pump
permanently. The use in contaminated water with solids and particles also leads to pre-
mature wear and negatively affects the life of the pump. Algae or others
Plants that settle around the filter basket and can clog it quickly lead to reduced water
flow and increased wear. We recommend operating the device exclusively in water wit-
hout plants or to ensure that no plants can be sucked in. Wear parts are excluded from
the warranty. Proper cleaning and care reduce wear on the device.
REPAIR
The motor can not be repaired if the cables or the housing are damaged and must the-
refore be replaced. The running unit (rotor + impeller) is available separately as a spare
part. If you have any questions or problems, contact an electrician or your dealer for
your own safety.
STORAGE
The unit must be taken out of service and dismantled in case of expected frost. First
clean the device as described under Cleaning and Maintenance. The device can be stored
dry or wet. If the device is to be stored dry, it is important that all components, including
the internal engine parts, are completely dry. Put in wet storage. Put the cleaned pump
in a container filled with fresh tap water. Please note that the container is set up frost-
free.
DISPOSAL
The device must be disposed of in accordance with national regulations. This device must
not be disposed of with household waste. Make the device unusable by cutting off the
cables and dispose of them via the return system provided for this purpose.
If lamps are included in the device, they must be disposed of using the return system
provided for this purpose.
Ask your dealer.