105
Capron - 04-17 - CAP-0017-01
EN
Appliances
10
Refrigerating temperature
control
When turned on the refrigerator automatically selects the thermostat position
selected last. This position can be adjusted manually by using the arrow keys
(Fig. 93,2). The illuminated bars of the cooling level indicator (Fig. 93,5) show
the selected thermostat position. The refrigerating temperature for the three
types of energy is set with the arrow keys. It takes a few hours till the refriger-
ator reaches its normal operating temperature. When changing over the oper-
ating mode the thermostat setting will be maintained. The refrigerating
temperature is retained regardless of the type of energy being used.
Switching on:
For gas operation, open the regulator tap on the gas bottle and the gas iso-
lator tap "Refrigerator".
Press and hold the On/Off button (Fig. 93,1) for 1 second. Button
(Fig. 93,1) lights up green. To save energy, after approximately
10 seconds the display is dimmed.
Press and hold the confirmation button (Fig. 93,3) for about 2 seconds. The
symbols for the operating modes (Fig. 93,4) are flashing.
Press the arrow keys (Fig. 93,2) to change the operating mode.
For gas operation, select the operating mode Gas using the arrow keys
(Fig. 93,2). Gas supply is open. Ignition will take place automatically. A
ticking sound can be heard until ignition has been completed successfully.
Press confirmation button (Fig. 93,3).
Press confirmation button (Fig. 93,3) again. The current cooling level is
shown by the illuminated bars (Fig. 93,5).
To change the setting, press the arrow keys (Fig. 93,2) until the desired
setting is displayed.
Switching off:
Press and hold the On/Off button (Fig. 93,1) for about 2 seconds. All lights
go out. Refrigerator is switched off.
In case of gas operation, close the gas isolator tap "Refrigerator" and the
regulator tap on the gas bottle.
Z
The refrigerator always requires a 12 V control voltage, regardless of which
type of energy it is using. The control voltage is present as soon as the
transformer/rectifier is switched on. Therefore the closed circuit current
always flows even if the refrigerator is switched off. Always switch off the
transformer/rectifier for a temporary lay-up.
Z
We recommend that the refrigerator be operated in 12 V operation when
the vehicle is in motion.
When the vehicle is stationary, we advise you to operate the refrigerator in
240 V operation, assuming a 240 V connection is available.
In all other cases, the refrigerator can be operated in gas operation.
X
Never let gas escape unburned due to danger of explosion.
X
It is not permitted to operate the refrigerator with car gas.
Z
Close the gas isolator tap "Refrigerator" when the refrigerator is operated
electrically.
Summary of Contents for Capron A361
Page 4: ...Contents 4 Capron 04 17 CAP 0017 01EN ...
Page 6: ...6 Capron 04 17 CAP 0017 01EN Warranty 1 ...
Page 10: ...10 Capron 04 17 CAP 0017 01EN Introduction 2 ...
Page 32: ...32 Capron 04 17 CAP 0017 01EN Before the journey 4 ...
Page 72: ...72 Capron 04 17 CAP 0017 01EN Gas system 8 ...
Page 152: ...152 Capron 04 17 CAP 0017 01EN Helpful notes 16 ...