92
Capron - 04-17 - CAP-0017-01
EN
Appliances
10
10.2.4
Heater and production of hot water (Truma Combi)
The power supply of the heating control system cannot be interrupted by
means of the 12 V main switch.
The heater is operated with gas.
Operating modes
The heater can be operated in different operating modes:
z
Winter operation (with or without production of hot water)
z
Summer operation (only production of hot water)
Selecting operating mode:
Set the operating mode using the rotary switch (Fig. 80,6).
Winter operation
In winter operation "Heater and production of hot water" (Fig. 80,5) the
domestic water is automatically heated up when the heater is switched on. If
the heater switches off after the required room temperature has been reached,
the domestic water will continue to heat up until the set water temperature has
been reached.
A temperature sensor next to the panel measures the room temperature.
In the operating mode "Only heater" (Fig. 80,4) the heater can be operated
with an empty domestic water container.
Switching on:
Open the regulator tap on the gas bottle and the gas isolator tap "Heater/
boiler".
Turn the temperature control knob (Fig. 80,8) on the operating unit to the
desired heating level.
Set rotary switch (Fig. 80,6) to winter operation "Only heater" (Fig. 80,4) or
to winter operation "Heater and production of hot water" (Fig. 80,5).
The green indicator lamp (Fig. 80,7) is on.
The circulation fan automatically switches on when the heater is activated.
Switching off:
Turn the rotary switch (Fig. 80,6) to " " (Fig. 80,3).
Close the gas isolator tap "Heater/boiler" and the regulator tap on the gas
bottle.
After switching off the heater, the circulation fan may still run for a moment to
use up the residual heat.
Z
If the heater is not in operation when there is a risk of frost, empty the
domestic water container.
Fig. 80
Operating unit
1 Summer operation water tempera-
ture 60 °C
2 Summer operation water tempera-
ture 40 °C
3 Off
4 Winter operation "Only heater"
5 Winter operation "Heater and produc-
tion of hot water"
6 Rotary switch (external ring)
7 Indicator lamp "Heater operation"
(green)
8 Temperature control knob
9 Indicator lamp "Heating up period of
production of hot water" (yellow)/
"Fault" (red)
Summary of Contents for Capron A361
Page 4: ...Contents 4 Capron 04 17 CAP 0017 01EN ...
Page 6: ...6 Capron 04 17 CAP 0017 01EN Warranty 1 ...
Page 10: ...10 Capron 04 17 CAP 0017 01EN Introduction 2 ...
Page 32: ...32 Capron 04 17 CAP 0017 01EN Before the journey 4 ...
Page 72: ...72 Capron 04 17 CAP 0017 01EN Gas system 8 ...
Page 152: ...152 Capron 04 17 CAP 0017 01EN Helpful notes 16 ...