12
Z-WAvE SPECIFICATIOn
Command Class
version
Secure
ZWAvEPLuS_InFO [0x5E]
v2
SWITCh_BInARy [0x25]
v1
yES
ASSOCIATIOn [0x85]
v2
yES
MuLTI_ChAnnEL_ASSOCIATIOn [0x8E]
v3
yES
ASSOCIATIOn_GRP_InFO [0x59]
v2
yES
TRAnSPORT_SERvICE [0x55]
v2
vERSIOn [0x86]
v2
yES
MAnuFACTuRER_SPECIFIC [0x72]
v2
yES
DEvICE_RESET_LOCALLy [0x5A]
v1
yES
POWERLEvEL [0x73]
v1
yES
SECuRITy [0x98]
v1
SECuRITy_2 [0x9F]
v1
SuPERvISIOn [0x6C]
v1
yES
METER [0x32]
v3
yES
APPLICATIOn_STATuS [0x22]
v1
COnFIGuRATIOn [0x70]
v1
yES
CRC_16_EnCAP [0x56]
v1
nOTIFICATIOn [0x71]
v8
yES
PROTECTIOn [0x75]
v1
yES
FIRMWARE_uPDATE_MD [0x7A]
v4
yES
MuLTI_ChAnnEL [0x60]
v4
yES
BASIC [0x20]
v1
yES
#9: Z-Wave specification
Endpoint 1:
Generic Device Class: GEnERIC_TyPE_SWITCh_BInARy
Specific Device Class: SPECIFIC_TyPE_POWER_SWITCh_BInARy
Description: represents the main B type socket, allows to
turn on/off connected device and measure its active power and en-
ergy consumption.
Endpoint 2:
Generic Device Class: GEnERIC_TyPE_METER
Specific Device Class: SPECIFIC_TyPE_SIMPLE_METER
Description: represents the uSB port, allows to measure its active
power and energy consumption.
Supported Command Classes: