19
ADvAnCED PARAMETERS
32. Alarm state duration
This parameter specifies the duration of alarm state. If a device send-
ing an alarm frame through the Z-Wave network sets alarm duration as
well, this settings are ignored.
Available settings:
1-32400
(in seconds)
Default setting:
600
(10min) Parameter size:
2
[bytes]
COLOUR SETTINGS
40. Power load for violet colour
This parameter determines maximum active power value, which when
exceeded, causes the LED frame to flash violet. Function is active only
when parameter 41 is set to 1 or 2.
Available settings:
1000-30000
(100.0-3000.0W, step 0.1W)
Default setting:
30000
(3000W) Parameter size:
2
[bytes]
41. LED frame colour when controlled device is on
When set to 1 or 2, LED frame colour will change depending on active
power and parameter 40. Other colours are set permanently and do
not depend on power consumption.
Available settings:
0
- illumination turned off completely
1
- colour changes smoothly depending on ac-
tive power
2
- colour changes in steps depending on ac-
tive power
3
- white,
4
- red,
5
- green,
6
- blue,
7
- yellow
8
- cyan
, 9
- magenta
Default setting:
1
Parameter size:
1
[byte]
42. LED frame colour when controlled device is off
This parameter defines the illumination colour after turning off.
Available settings:
0
- illumination turned off completely
1
- LED frame is illuminated with a colour cor-
responding to the last measured power, before
the controlled device was turned off
3
- white,
4
- red,
5
- green,
6
- blue,
7
- yellow
8
- cyan,
9
- magenta
Default setting:
0
Parameter size:
1
[byte]
NOTE
The alarm may be can-
celed by pressing and
holding the button.
i