Temperature measurement compensation (Parameter Number 73, Parameter Size 2) temperature value to
be added to or deducted from the current measured temperature
Value
Description
64536 — 1000
Z-Wave range test interval (Parameter Number 80, Parameter Size 1) Time period between the consecutive
Z-Wave network range tests
Value
Description
0 — 17 0 – Z-Wave network range test inactive (Default 1)
Temperature alarm threshold (Parameter Number 81, Parameter Size 1) Temperature value, above which
the temperature alarm is sent
Value
Description
0
0 – temperature alarm inactive
2 — 100 (Default 54)
Smoke Sensor sensitivity (Parameter Number 82, Parameter Size 1) There are 3 levels of sensitivity to
smoke presence. Level 1 means the highest sensitivity.
Value
Description
1
HIGH Sensitivity
2
MEDIUM Sensitivity (Default)
3
LOW Sensitivity
Black Box sensitivity level (Parameter Number 83, Parameter Size 1) Parameter specifies temperature and
smoke level after which the Black Box starts recording them
Value
Description
1
HIGH Sensitivity
2
MEDIUM Sensitivity
3
LOW Sensitivity
(c) 2012 Z-Wave Europe GmbH, Goldbachstr. 13, 09337 Hohenstein-Ernstthal, Germany, All rights reserved, www.zwaveeurope.com - pp 11