background image

Value

Description

0

0 – tamper alarm inactive

1

1 – tamper alarm active, with cancellation option available (Default)

2

2 – tamper alarm active, without cancellation option

Command Classes

Supported Command Classes

Battery (version 1)

Basic (version 1)

Wake Up (version 1)

Association (version 2)

Version (version 2)

Multilevel Sensor (version 1)

Time Parameters (version 1)

Multi Channel Association (version 2)

Configuration (version 1)

Manufacturer Proprietary (version 1)

Manufacturer Specific (version 1)

Powerlevel (version 1)

Firmware Update Meta Data (version 1)

Alarm Sensor (version 1)

Technical Data

Explorer Frame Support Yes

SDK

4.54.02

Device Type

Slave with routing capabilities

Generic Device Class

Alarm Sensor

Specific Device Class

Routing Alarm Sensor

Routing

No

FLiRS

No

Firmware Version

2.1

Explanation of Z-Wave specific terms

(c) 2012 Z-Wave Europe GmbH, Goldbachstr. 13, 09337 Hohenstein-Ernstthal, Germany, All rights reserved, www.zwaveeurope.com - pp 13 

Summary of Contents for FIB_FGSS-101

Page 1: ...cation in smart homes and buildings It is using the frequency of 868 42 MHz to realize a very stable and secure communication Each message is reconfirmed two way communication and every mains powered...

Page 2: ...n of the country specific installation guidelines norms may do works with 230 Volt mains power Prior to the assembly of the product the voltage network has to be switched off and ensured against re sw...

Page 3: ...c 2012 Z Wave Europe GmbH Goldbachstr 13 09337 Hohenstein Ernstthal Germany All rights reserved www zwaveeurope com pp 3...

Page 4: ...c 2012 Z Wave Europe GmbH Goldbachstr 13 09337 Hohenstein Ernstthal Germany All rights reserved www zwaveeurope com pp 4...

Page 5: ...c 2012 Z Wave Europe GmbH Goldbachstr 13 09337 Hohenstein Ernstthal Germany All rights reserved www zwaveeurope com pp 5...

Page 6: ...I Note the inclusion process may be performed ONLY in direct range of the main controller 2 If the sensor is to be VDC powered drill holes in sensor s holder Note the sensor may be connected to a wire...

Page 7: ...ION Fibaro Smoke Sensor responds to physical presence of smoke Smoke presence is required for the device to react Fibaro Smoke Sensor performs a self test each 5 seconds and checks for smoke presence...

Page 8: ...de ID to 255 to send wakeup notifications as broadcast In this mode device takes more time to go to sleep and drains battery faster but can notify all it s direct neighbors about a wakeup Node Informa...

Page 9: ...eded to set a value of 200 minus 256 minus 56 In case of two byte value the same logic applies Values greater than 32768 may needed to be given as negative values too Smoke alarm cancellation delay Pa...

Page 10: ...ve temperature reports Value Description 0 17280 0 Reports inactive Default 0 Temperature report hysteresis Parameter Number 12 Parameter Size 1 temperature change resulting in a temperature report Va...

Page 11: ...mperature alarm is sent Value Description 0 0 temperature alarm inactive 2 100 Default 54 Smoke Sensor sensitivity Parameter Number 82 Parameter Size 1 There are 3 levels of sensitivity to smoke prese...

Page 12: ...Value Description 1 17280 360 means 30min Default 360 Low battery alarm Parameter Number 87 Parameter Size 2 Time interval in which low battery alarm if detected is repeated using visual and acoustic...

Page 13: ...ssociation version 2 Configuration version 1 Manufacturer Proprietary version 1 Manufacturer Specific version 1 Powerlevel version 1 Firmware Update Meta Data version 1 Alarm Sensor version 1 Technica...

Page 14: ...ice and a controlled device Wakeup Notification is a special wireless message issued by a Z Wave device to annonces that is is able to communicate Node Information Frame is a special wireless message...

Reviews: