background image

14

BATTERY

To add an association

 (using the home Center controller):

1.  Go to the device options by clicking the icon: 
2.  Select the „Advanced” tab.
3.  Click the “Setting Association” button.
4.  Specify to which group and what devices are to be associated.
5.  Save the changes.
6.  Click 

 

and 

 

simultaneously to wake up the device.

Paired buttons associations

After pairing buttons, horizontal pairs of buttons (  and  ,   and  , 

 and  ) work as one button and send associations to left buttons 

groups only. 
Left buttons ( ,  ,  ) turn on associated devices and right buttons  

( ,  ,  ) turn them off. 
In multilevel association groups (3, 7, 11) left buttons increase level 

while holding and right buttons decrease it.

To pair buttons:

 

1.  Change settings of parameters:

• 

 and   – set parameter 6 to value 1

• 

 and 

 

– set parameter 7 to value 1

• 

 and 

 

– set parameter 8 to value 1

2.  Save the changes.
3.  Click 

 

and 

 

simultaneously to wake up the device.

The KeyFob in 2nd to 13th group allows to control 5 de-

vices (regular or multichannel) per an association group. 

 

“LifeLine” group is reserved solely for the controller and hence only 1 

node can  be assigned.
It is not recommended to associate more than 10 devices in general, 

as the response time to control commands depends on the number of 

associated devices. In extreme cases, system response may be delayed.

Summary of Contents for KEYFOB FGKF-601

Page 1: ...n and features 3 2 Basic activation 4 3 Adding removing the device 5 4 Operating the device 6 5 Visual indications 7 6 Lock Mode 8 7 Sequences 10 8 Activating scenes 11 9 Battery 12 10 Associations 13...

Page 2: ...y the compliance with additional standards General information about the FIBARO System FIBARO is a wireless smart home automation system based on the Z Wave protocol All of available devices can be co...

Page 3: ...te control Six buttons allow you to control other devices through the Z Wave network and run various scenes defined in FIBARO System Configure actions for one two three clicks holding the button and b...

Page 4: ...se the battery cover by turning it clockwise 4 Locate the device nearby the main Z Wave controller 5 Set the main Z Wave controller in Security non Security Mode add mode see the controller s manual 6...

Page 5: ...ssage and green LED colour NOTE Adding in Security Mode must be per formed up to 2 meters from the controller i NOTE In case the device is not added please re set the device and re peat the adding pro...

Page 6: ...device to factory defaults Reset procedure allows to restore the device back to its factory set tings which means all information about the Z Wave controller and user configuration will be deleted The...

Page 7: ...o activate scenes associations Green to red transition Device locked using button hold Battery 3 magenta pulses Low battery Replace the battery Configuration 2 white pulses Device woken up Device stat...

Page 8: ...in Lock Mode section 4 Select sequence of 2 to 5 buttons click Next 5 Select time to lock and locking button click Next 6 Click and simultaneously to wake up the device 7 Wait for the device to config...

Page 9: ...ed value 3 Click and simultaneously to wake up the device 4 Wait for the device to configure Button Value 1 2 3 4 5 6 Setting time to lock and locking button using advanced parameter 1 Calculate value...

Page 10: ...g sequences Maximum of six sequences can be created Each sequence must be unique Sequence can consist of two to five button pushes Sequence can contain multiple clicks of the same button Setting a new...

Page 11: ...n parameters 21 26 Activating a double click will introduce delay to a single click reaction and activating a triple click will introduce delay to a double click reaction Button Scene ID 1 2 3 4 5 6 S...

Page 12: ...ed battery Estimat ed battery life with device added once default settings direct range and maximum 5 pushes per day is 2 years o s e o s e 1 1 Using included keyring or a coin open the battery cover...

Page 13: ...th association group Triangle Multilevel is assigned to click ing and holding the button and is used to turn on off and change level of associated devices 10th association group Minus On Off is assign...

Page 14: ...them off In multilevel association groups 3 7 11 left buttons increase level while holding and right buttons decrease it To pair buttons 1 Change settings of parameters and set parameter 6 to value 1...

Page 15: ...ck Mode on page 9 for more information Available settings 0 Lock Mode disabled 5 1791 calculated value Default setting 60 60s Parameter size 2 bytes 3 First scene sequence This parameter allows to set...

Page 16: ...ormation Available settings 0 4th sequence disabled 9 28086 value of sequence Default setting 0 Parameter size 2 bytes 7 Fifth scene sequence This parameter allows to set up sequence that activates sc...

Page 17: ...ting 255 Parameter size 2 bytes 17 Paired buttons association for and This parameter allows to activate paired buttons association mode for and buttons Paired buttons are dependent and association are...

Page 18: ...Parameter size 1 byte 29 Associations in Z Wave network Security Mode Parameter defines how commands are sent in specified associa tion groups using Security Mode or not Parameter is active only in Z...

Page 19: ...16 0 MHz US 921 4 921 42 or 919 8 MHz ANZ 869 0 or 869 02 MHz RU up to 50m outdoors up to 40m indoors Depending on terrain and building structure 70 x 38 x 15 mm CAUTION Using batteries other than spe...

Page 20: ...separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio TV te...

Page 21: ...characteristics and func tions of the original design of the certified lower power frequency elec tric machinery Article 14 The application of low power frequency electric machineries shall not affec...

Reviews: