29
Figure 30:
Device configuration document
This document includes, as a minimum, the following tags:
<DeviceIdentification>
- this parameter must be the actual name of the unit being addressed,
or the unit will not respond. The notation
HZONE-X
indicates the affected hyperzone.
<ConfigurationSettingName>
- the configuration parameters being changed are added to this
line of text. If one of the settings is out of range, or a parameter name is invalid, the APU
responds with a
<Device Configuration>
message that includes the heading:
<DeviceConfiguration MessageType=“Response” RequestID=“X” Status=“Failed”
X
denotes the incoming
RequestID
. The current settings of the APU are included in this
response message, but only the settings before the error line are changed.
Upon successful configuration adjustment, an identical message is returned with all actual
parameters, and the following message heading:
<DeviceConfiguration
MessageType=“Response” RequestID=“X” Status=“OK”