Pierce the cover plate with
diagonal pliers along the
edges desired for making
a wiring hole
12
9
Preparations for Cable Connection
Before laying out wires and cables, you need to remove the front panel of the PDP. If space is
limited for operations, remove the baffle at the bottom of the PDP as well.
After you have completed layout of wires and cables, restore the front panel and baffle to their
original places.
Internal cables are connected inside a cabinet. Usually they have been connected before
delivery. Installers should check the connection of internal cables on site. The items to check
include whether the cable distribution is reasonable, whether the wires and cables are properly
and neatly arranged, whether the plugs are connected firmly, whether incorrect or poor insertion
exists, and whether any part is missing.
Installers can choose the top access wiring mode or the floor access wiring mode according to
the equipment room and the installation site conditions (This guide uses the top access wiring
mode as an example).
The AN6000-15 uses the PDP850A (3000064).
For a cabinet equipped with mouseproof hop-pockets
on the top, fasten the mouseproof hop-pockets after
external wires and cables are led into the cabinet and
well arranged.
For a cabinet equipped with a cover plate on the top or
bottom, determine the position, size and number of
wiring holes according to the wiring plan. Pierce the
cover plate with diagonal pliers at desired positions to
make wiring holes. The following introduces how to
make wiring holes on the top of the cabinet.
Prepare the holes from near to far in sequence.
Polish the raw edges of the holes so that they will
not cut hands or cables.
Preparing Wiring Holes on the Cabinet
Fastening the mouseproof hop-
pockets on the top of the cabinet
12
Instruction
Note
Instruction
Recommended Areas and
Sequence for Making Wiring Holes
Making a Wiring Hole
L
M
R
L
M
R