background image

 

 

 

 

PHYSICAL

 

SPECIFICATIONS

 

 

Length

Width

 

Height

 

Weight

Case

 

Dimensions

 

(2U)

 

13

 

in

 

(330

 

mm)

19

 

in

 

(482

 

mm)

 

3.5

 

in

 

(133

 

mm)

16.6 lb

 

(7.5 kg)

 

ELECTRICAL

 

SPECIFICATIONS

 

 

Min

 

Typ

Max

Power

 

Requirement

 

with

 

PSMAC

 

Voltage

 

Range

 

(VAC)

90

 

‐ 

230

Power

 

Consumption

 

(W)

‐ 

65

Power

 

Requirement

 

with

 

PSMDC

 

Voltage

 

Range

 

(VDC)

36

 

‐ 

72

Power

 

Consumption

 

(W)

‐ 

65

 

External

 

SFP

 

Interfaces

 

(1

16)

 

Min

 

Typ

Max

Data

 

Rate

 

(MB)

 

155

 

‐ 

3000

Recommended

 

Jitter

 

(psec)

 

‐ 

40

Operating

 

Voltage

 

(VDC)

 

‐ 

3.3

Maximum

 

Current

 

(mA)

 

‐ 

‐ 

350

 

Internal

 

CDWM

 

Optical

 

Interfaces

 

Min

 

Typ

Max

Aggregate

 

Optical

 

Launch

 

Level

 

(dB)

 

1

 

0

 

+1

Aggregate

 

Receiver

 

Sensitivity

 

25

 

24.5

22

CWDM

 

Wavelengths

 

Ch1

 ‐

1610nm

Ch2

 ‐

1590nm

 

Ch3

 ‐

1570nm

Ch4

 ‐

1550nm

 

Ch5

 ‐

1530nm

Ch6

 ‐

1510nm

 

Ch7

 ‐

1490nm

Ch8

 ‐

1470nm

 

Ch9

 ‐

1450nm

Ch10

 ‐

1430nm

 

Ch11

 ‐

1410nm

Ch12

 ‐

1390nm

 

Ch13

 ‐

1370nm

Ch14

 ‐

1350nm

 

Ch15

 ‐

1330nm

Ch16

 ‐

1310nm

 

 

Environmental

 

Storage

 

Temperature

 

(°C)

40

 

‐ 

85

Operating

 

Temperature (°C)

0

 

‐ 

50

 

Aggregate

 

Interface

 

Connector

 

Neutrik

 

opticalCON

 

DUO

 

(LC)

 

 

 

 

 

 

Summary of Contents for WDM16

Page 1: ...USER MANUAL Active Wave Division Multiplexer WDM16 WDM8A WDM8B...

Page 2: ......

Page 3: ...us the apparatus has been exposed to rain or moisture does not operate normally or has been dropped The apparatus shall not be exposed to dripping or splashing No objects filled with liquids such as v...

Page 4: ...I equipment must be earthed separately Grounding the unit is one of the measures for protection against electrical shock hazard dangerous body currents Hazardous voltage may not only be caused by defe...

Page 5: ...sal of Used Equipment Used equipment contains valuable raw materials as well as substances that must be disposed of professionally Please dispose of used equipment via an authorized specialist dealer...

Page 6: ...Active Wave Division Multiplexer Combines 16 or 8 optical channels into a single fiber pair Each channel independently supports data rates from 155 MB up to 3 GB SMPTE compatible internal fiber optics...

Page 7: ...the number of Active Wave Division channels and the associated internal wavelengths that are supported The chassis dimensions and power supplies remain identical The WDM16 supports all of the 16 stand...

Page 8: ...if there is mechanical damage or if the unit fails to operate notify FiberPlex and make the shipping materials available for the carrier s inspection Chassis Mounting Mount the chassis using fastener...

Page 9: ...ystem is functioning normally PS1 Shows status indication of the power supply in PS Slot 1 top slot Color indications can be interpreted using the following table LED State Condition Off No power supp...

Page 10: ...INF 8074i more information later in this manual They are fixed bi directional ports and cannot support dual TX or dual RX SFPs Any standard MSA complaint SFP can be used in these slots including but n...

Page 11: ...Power Supply Module AC Inlet Power is provided through a Neutrik powerCON TRUE1 connector Connect to 100 240 VAC power source using the supplied AC power cord Fuse Compartment Contains the fuse for th...

Page 12: ...lete redundancy The second supply can be inserted at any time in the unused power supply slot Insert the supply first then apply external AC power The PSMAC and the WDM16 8 support hot swapping of the...

Page 13: ...REMOVE CAP REPLACE FUSE SCREWDRIVER SLOT Figure 6 Replacing the Fuse in the PSMAC...

Page 14: ...e SFP Module has a Bail Clasp close the Bail Clasp before inserting the SFP Module 4 With the gold finger connector on the bottom and the label on the top line up the SFP Module with the empty cage an...

Page 15: ...Tab Pull the tab gently in a straight outward motion until it disengages from the port Make sure the tab is not twisted when pulling as it may become disconnected from the SFP Module Slide Tab With y...

Page 16: ...nnecting the cable requires grasping the cable connector with your full hand and pulling back the release ring with your thumb and fore finger while pulling the connector straight out See Neutrik docu...

Page 17: ...the WDM16 The pinouts of the connectors are as follows Connector Pin Function 1 Rx to the WDM 2 RX to the WDM 3 TX from the WDM 4 TX from the WDM A standard crossover RJ11 cable can be used to daisych...

Page 18: ...gical conditions allowing the longer sequences of ones or zeros to pass without error The Fiberplex Technologies WDM16 and WDM8 Active Coarse Wave Division Multiplexer has Video Enhanced optics pre in...

Page 19: ......

Page 20: ...WDM16 Specifications 19 00 482 6 3 00 76 2 3 47 88 1 18 33 465 5 25 6 4 17 25 438 2 13 12 333 2 13 62 346 0 Figure 10 WDM16 8 Overall Dimensions...

Page 21: ...ax Data Rate MB 155 3000 Recommended Jitter psec 40 Operating Voltage VDC 3 3 Maximum Current mA 350 Internal CDWM Optical Interfaces Min Typ Max Aggregate Optical Launch Level dB 1 0 1 Aggregate Rece...

Page 22: ...n 286 mm 2 625 in 67 mm 1 25 in 32 mm 1 1 lb 0 5 kg SPECIFICATIONS AC POWER SUPPLY Min Typ Max Power Supply Input Voltage VAC 100 110 240 Input Frequency Hz 40 400 Power Factor 92 Output 1Voltage VDC...

Page 23: ......

Page 24: ...WDMUM 1401 18040 412 Guilford Rd Annapolis Junction MD 20701 fiberplex com clients fiberplex com 301 604 0100...

Reviews: