Reproduction forbidden without Fibocom Wireless Inc. written authorization - All Rights Reserved
FIBOCOM L610-LA Series Hardware Guide
Page 24 of
49
Parameter
Mode
Condition
Average
Typ.Current(mA)
I
off
Power off
Module power off
0.013
I
idle
Idle
Idle(AT+cfun=0)
12
I
sleep
GSM
MFRMS=5
2.3
LTE FDD
Paging cycle #128 frames
2.5
I
GSM-RMS
GSM
GSM850 PCL5
260
EGSM900 PCL5
260
DCS1800 PCL0
200
PCS1900 PCL0
200
I
GPRS-RMS CS4
GPRS
GPRS Data transfer GSM850; PCL=5;
1Rx/4Tx
480
GPRS Data transfer GSM900; PCL=5;
1Rx/4Tx
480
GPRS Data transfer DCS1800; PCL=0;
1Rx/4Tx
400
GPRS Data transfer PCS1900; PCL=0;
1Rx/4Tx
400
I
LTE-RMS
LTE FDD
LTE FDD Data transfer Band 1 @+23dBm 730
LTE FDD Data transfer Band 2 @+23dBm 780
LTE FDD Data transfer Band 3 @+23dBm 730
LTE FDD Data transfer Band 4 @+23dBm 730
LTE FDD Data transfer Band 5 @+23dBm 600
LTE FDD Data transfer Band 7 @+23dBm 730
LTE FDD Data transfer Band 8 @+23dBm 600
LTE FDD Data transfer Band 28
@+23dBm
600
LTE FDD Data transfer Band 66
@+23dBm
730
3.3 Control Signal
L610 modules provide two control signals for power on/off and reset operations. The pin definitions are as
follows:
Pin Name I/O Pin
Description
RESET_N I
20
When the module is in work, pull down RESET for Tst (100ms), and then