Reproduction forbidden without Fibocom Wireless Inc. written authorization - All rights reserved.
FIBOCOM MC610 Series Hardware Guide
60/70
Test Item
Test Condition
40 °C and +85 °C for 0.5 h, and the temperature conversion time
is < 3 min
High temperature and humidity
test
The temperature is +65 °C ± 3 °C, the humidity is 90 to 95% RH,
and the Power OFF state lasts for 88 hours
Low-temperature running test
The temperature Is -30 °C ± 3 °C, and the working condition lasts
for 24 hours
High-temperature running test
The temperature is +75°C ± 3°C, and the working condition lasts
for 24 hours
Vibration test
Frequency
Random vibration ASD (acceleration
spectral density)
5 to 20Hz
0.96m
2
/s
3
20 to 500Hz
0.96 m
2
/s
3
(at 20Hz), other -3dB/octave
Test for connector lifetime
Insert and pull the RF antenna interface cable for 30 times
5.5 ESD Characterization
In the design of MC610 series modules, ESD problems have been considered and ESD protection has
been done. However, ESD problems may occur during transportation and secondary development.
Therefore, developers should consider the protection of ESD problems of final products. In addition to
anti-static treatment of packaging, customers should refer to the recommended circuit of interface design
in the document.
Refer to the following table for the allowable ESD discharge range of MC610 series modules.