background image

4/8/16E1 Multiplexer User Manual V2.1 

Beijing Fibridge Co., Ltd. 

Tel: +8610-58858988 Fax: +8610-58858520 http://www.fibridge.com 

- 25 - 

5.6.2.  LEDs of the EOW Module 

Table14 LEDs description of the EOW Module 

LEDs Color 

Status

Description 

PWR Green ON 

Power work state indicator. 

PWR is ON when Power supply ok. 

ACT Yellow 

ON 

EOW work state indicator. 

ACT blinks when EOW Module works properly. 

TMP Red 

ON 

Temperature alarm indicator.   

TMP is ON When temperature of slots chassis is 

over 70 

 

 

LOS1- 

LOS8 

Red ON 

LOSx (x=1~8) is ON When the relevant E1 

Channel Signal loses.   

NOP Red 

ON 

NOP is ON when no optical signals is detected by 

RX of Optical Port.   

LOF Red 

ON 

LOF is ON when Optical Line loses

synchronization. IE-3 and IE-6 Alarm are masked 

when LOF alarm occurs. 

IE-3 Red 

ON 

1E-3 is ON when optical line’s bit error rate is over 

10

-3

.  

IE-6 Red 

ON 

1E-6 is ON when optical line’s bit error rate is over 

10

-6

.  

LTR1- 

LTR4 

Yellow 

ON/ 

Blink

Ethernet x (x=1~4) Link/TX/RX indicator.   

LTR x (x=1~4) is ON when the Ethernet port of the 

local device links properly, LTR x (x=1~4) blinks

when the Ethernet1 port of the local device is 

transmitting or receiving data. 

Summary of Contents for F9-480 Series

Page 1: ...F9 480 Series 4 8 16E1 Plus Ethernet Multi service Multiplexer User Manual Version 2 1 Beijing Fibridge Co Ltd...

Page 2: ...pology 6 4 Specification 6 4 1 Optical Port 6 4 2 E1 Port 7 4 3 Ethernet Port 7 4 4 Phone Port 7 4 5 Data Port 7 4 6 Management Port 8 4 7 Power Supply 8 4 8 Operating Environment 9 4 9 Device Size 9...

Page 3: ...ibridge com 2 6 Installation Maintenance 28 6 1 Install the Module and Chassis 28 6 2 Install the Standalone device 29 6 3 Using Phone 30 6 4 Maintenance 31 7 Order Information 31 7 1 Model 31 7 2 Par...

Page 4: ...lete alarm functions one RS232 485 asynchronous interface and remote branch loop back functions At the same time it can be monitored from Fi View MP management software First of all Multi service Mult...

Page 5: ...232 and Ethernet port for management z Standalone and chassis optional 220VAC and 48VDC optional 2 2 Software Features z Support local and remote management z Support Console WEB and SNMP management z...

Page 6: ...e update tool and new version firmware file download from our website z Provide MIB file make it easy to be integrated into the third party SNMP management software z Adopt the centralized management...

Page 7: ...opology F9 100M represents standalone of the Multi service Multiplexer Figure2 Star Topology 4 Specification 4 1 Optical Port z Bit rate 150Mb s 50ppm z Wavelength 1310nm 1550nm z Output power 11 to 4...

Page 8: ...ter Compliant with ITU T G 742 and G 823 z Unframed mode z Numbers 4 8 16 optional 4 3 Ethernet Port z Compatible with IEEE802 3 IEEE802 3u z Speed 10 100MpbsMbps z Full Half duplex auto negotiating z...

Page 9: ...of the Data DB9 PIN 2 3 5 1 4 6 7 8 9 Protocol RS232 RS485 Definition RX TX GND N A TX Z TX Y RX B RX A 4 6 Management Port z Type Console management z Protocol RS232 bit rate 9600bps or 19200bps z Co...

Page 10: ...ity 95 no condensing 4 9 Device Size z 4 8E1 Standalone device 434mm W 44mm H 200mm D z 16E1 Standalone device 434mm W 44mm H 234mm D z Chassis size 19 inch W 6U H 300mm D 5 Device Panel 5 1 4 8E1 Mul...

Page 11: ...r Stat Description PWR Green ON Power Supply OK ARL Red ON Blink ARL is on When local device has any alarm ARL blinks when remote device has alarm but no alarm at local device OPTB Green ON Optical B...

Page 12: ...Ethernet2 port of the local device is transmitting or receiving Data FD2 Green ON Ethernet2 Half Full Duplex status indicator FD2 is on when the Ethernet2 port of the local device is working at Full D...

Page 13: ...TE When the button of Local Remote is pressed down as this led shows the status of remote device Opposite when up as the led shows the status of local device ALARM ALARM MUTE MUTE When the button of A...

Page 14: ...l DB37 Connector connected by an adapter E1 4 1 1 st 4 th E1 Channel DB37 Connector connected by an adapter Mgt Management Console port RS232 DB9 Connector Data RS232 RS485 Data port DB9 Connector Not...

Page 15: ...Multiplexer Description Table6 LEDs Description of the 16E1 Multiplexer LEDs Color Stat Description PWR Green ON Power Supply OK ARL Red ON Blink ARL is on When local device has any alarm ARL blinks w...

Page 16: ...thernet2 port of the local device is working at 100Mbps speed FDX1 Green ON Ethernet1 Half Full Duplex status indicator FD1 is on when the Ethernet1 port of the local device is working at Full Duplex...

Page 17: ...Red ON 1E 6A is on when optical A line s bit error rate is over 10 6 IE 6B Red ON 1E 6B is on when optical B line s bit error rate is over 10 6 Note The Work NOP LOF 1E 3 1E 6 LOS LTR SPD FDX LEDs wil...

Page 18: ...ARM ALARM MUTE MUTE When pressed down as the alarm sound is mute When pressed up as the device sounds when any of the alarms occurs MASK Switch Button When press this button once any of the current E1...

Page 19: ...85 Data port DB9 Connector Note Above description is include all the ports The ordered device maybe haven t some of the ports such as optical B ETH1 ETH2 etc 5 3 Chassis of E1 Multi service Multiplexe...

Page 20: ...ule For 48VDC power input user needn t install any Power Module User only need to connect the 48V power input connector to the 48VDC power source 5 3 2 Back View of the Chassis Figure8 Back Panel View...

Page 21: ...988 Fax 8610 58858520 http www fibridge com 20 5 4 1 Panel sketch map of the 2 4E1 Multi service Multiplexer Module Figure9 The Panel of the 2 4E1 Left and 8E1 Multiplexer Module 2 Ethernet Optical Ph...

Page 22: ...ALARM status of remote device PHONE Green ON Blink PHONE blinks When one calling but haven t been talking PHONE is on When talking 5 4 3 User Interface of the 2 4E1 Module Table11 User interface descr...

Page 23: ...er work state indicator PWR is ON when Power supply ok ARL Red ON Blink ARL is ON When local device has any alarm ARL blinks when remote device has alarm but no alarm at local device When button of Lo...

Page 24: ...10 100Mbps Half Full Duplex OPTA Optical A OPTB Optical B for redundant backup DATA RS232 RS485 are Both OK DB9 connector PHS For phone use one MDI UTP to connect to the EOW Module 5 6 EOW Module EOW...

Page 25: ...d Tel 8610 58858988 Fax 8610 58858520 http www fibridge com 24 5 6 1 Panel sketch map of the EOW Module Figure10 The Panel map of the EOW Module Console Management Port LED panel Phone Jack Buttons LE...

Page 26: ...is over 70 LOS1 LOS8 Red ON LOSx x 1 8 is ON When the relevant E1 Channel Signal loses NOP Red ON NOP is ON when no optical signals is detected by RX of Optical Port LOF Red ON LOF is ON when Optical...

Page 27: ...the Number of which is appeared on the LED Panel 2 For 2 port Ethernet Multi service Multiplexer Module LTR3 4 FD3 4 SPD3 4 is not available 3 The NOP LOF 1E 3 1E 6 LOS LTR SPD FDX LEDs will show the...

Page 28: ...ice sounds when any of the alarms occurs LOCAL REMOT When the button of Local Remote is pressed down as this led shows the status of remote device Opposite when up as the led shows the status of local...

Page 29: ...wer input to the proper power source NOTE 48VDC and 220VAC can t be used at the same time z Fasten the device to the proper place z Power ON Please check whether any unexpected LEDs esp RED LEDs are O...

Page 30: ...attachment contradistinguish to the Packing List z Connect the ports to other proper device For example connect the Ethernet port to the PC or the switch connect the E1 port to PBX etc z Connect the...

Page 31: ...phone of the standalone z On the Chassis end sounds appear and the PHONE led of the relative Multi service Multiplexer Module blinks z Use one UTP to connect the PHS jack between the EOW and the relat...

Page 32: ...ke care of the Optical port avoid of any hurt from the laser z There maybe none problem when ARL led is ON for unused E1 can cause LOS and ARL led ON z Use Local Remote button to switch the status ind...

Page 33: ...ptical port and optical port has ALS function F9 2402 XXX23 8E1 Multi service Multiplexer with redundant backup optical port F9 2403 XXX23 8E1 Multi service Multiplexer optical port has ALS function F...

Page 34: ...9 1204 XXX23M 4E1 Multi service Multiplexer with redundant backup optical port and optical port has ALS function F9 2402 XXX23M 8E1 Multi service Multiplexer with redundant backup optical port F9 2403...

Page 35: ...ove P N means 2 10 100Mbps Ethernet port 7 4 Part Number P N of the Chassis FC 912 6U height 14 slots up to 12 slots for Multi service Multiplexer Modules FC 912 M Management Module of the FC 912 supp...