14
1-3~1-8 Undefined
Bit
Function
ON
OFF
2
-
1
Handshaking
(BUSY
condition)
Receive buffer full
Off line or receive
buffer full
2
-
2
Reserved (Do not change settings)
2
-
3
2
-
4
Print density /
Low power
consumption
Refer to Table A
2
-
5
Change receive
buffer BUSY
condition (If
data buffer
capacity set to
4KB.)
When the remaining
receive buffer capacity
is 138 bytes, change
BUSY condition.
When the remaining
receive buffer capacity
is 256 bytes, change
BUSY condition.
2
-
6
~
2
-
7
Reserved (Do not change settings)
2
-
8
On, 0x0d enabled
Table A
Print density / Low power consumption
SW 2-3
SW 2-4
- Low power consumption mode
ON
ON
1 Normal density
OFF
OFF
2 Medium density
ON
OFF
3 High density
OFF
ON
Chapter 3 Command List
Command
Name
HT
Horizontal tab
LF
Print and line feed
FF
Print and return to standard mode (in page mode)
CR
Print and carriage return
CAN
Cancel print data in page mode
DLE EOT
Real-time status transmission
DLE ENQ
Real-time request to printer
DLE DC4
Generate pulse at real-time
ESC FF
Print data in page mode
ESC SP
Set right-side character spacing