27
Contact your dealer for other details.
10.2 Default Settings of Built-in WIFI Module
•
SSID = USR-WIFI232-T
•
Protocol = TCP-Server
•
Port ID = 8899
Contact your dealer for other details.
10.3 Comport Setting Procedures
Following the below procedures to setup comports.
a.
Go to F16 or F17.
•
F16 is used to configure Comport 1.
•
F17 is used to configure Comport 2.
b.
Press
[Func]
or
[Unit]
to shift among parameters Off, PC, Scanner,
CMD, Auto1, Auto 2, Auto 3 and Manual.
Notes: -
•
Off = Comport disable. Select this when a particular comport is not
used.
•
Scanner, PC & CMD is data string related modes.
•
Auto 1, Auto 2, Auto 3 and Manual are print related modes.
•
All working modes (except Off, LP50 and TSC) accept scanner data
input during operation.
•
All working modes (except Off, LP50 and TSC) accept and
responses to System Parameter Inquiry and also System Parameter
Setting commands during operation.
•
When both ports are set to data string related modes,
[Print/M+]
key
is used as M+ (memory accumulation) and can only be activated
when value is stable and ≥ 20d.
•
If both comports are set to print related mode, then maximum only
one comport should be set with Auto Memory Accumulation = On.
c.
Select the preferred output type parameters then press
[Print/M+]
to
save.
d.
At this point: -
•
If PC is selected, refer to
10.3.1
for setting details.
•
If CMD is selected, refer to
10.3.2
for setting details.
•
If Manual is selected, refer to
10.3.3
for setting details.
•
If Auto 1~3 is selected, refer to
10.3.4
for setting details.
Summary of Contents for CSa
Page 2: ...2 ...
Page 9: ...9 2 Specifications ...
Page 10: ...10 3 Keys Display Connection Points ...
Page 53: ...53 Appendix B PC Output Protocols ...
Page 54: ...54 ...
Page 55: ...55 ...
Page 56: ...56 ...
Page 72: ...72 Fidelity Measurement Co Ltd www fi measurement com e mail info fi measurement com ...