63
d3
= auto zero tracking
speed: - 00 = Off; 01 =
0.25e; 02 = 0.50e; 03 =
10e; 04 = 1.5e; 05 = 2.0e;
06 = 2.5e; 07 = 3.0e; ….;
09 = 5e; 10 = 7.5e; 11 =
10e
An
Auto tare, repetitive
tare and preset tare
d1
= auto tare: - 0 = Off; 1
= On; 2= Continuous
d2
= repetitive tare: - 0 =
Off; 1 = On
d3
= Preset tare: - 0 = Off;
1 = On
Ao
Stability control of
manual zero and
manual tare
d1
= manual zero stability
control: - 0 = no (disable);
1 = Yes (enable)
d2
= manual tare stability
control: - 0 = no (disable);
1 = Yes (enable)
Ap
Auto power off time,
backlight brightness,
auto power saving,
keypad buzzer and
system buzzer
d1
= auto power off time: -
0 = Off; 1 = 1 minute; 2 = 3
minute; 3 = 5 minute; 4 =
10 minute; 5 = 20 minute
d2
= backlight brightness
(01 ~ 04). 01 = lowest, 04
= highest.
d3
= auto power saving: -
00 = Off; 01 = On
d4
= keypad buzzer: - 0 =
Off; 1 = On
d5
= system buzzer: - 0 =
Off; 1 = On
Aq
Check result buzzer,
near zero value,
high limit for
d1
= check result buzzer: -
0 = Off; 1 = In; 2 = Out; 3 =
hi, 4 = lo
Summary of Contents for CSa