Line-interactive UPS 

 

1000 R1U 

 

User Manual 

 

 

 

IMPORTANT SAFETY INSTRUCTIONS 

 

(SAVE THESE INSTRUCTIONS) 

 

This manual contains important safety instructions. Please read and follow all instructions carefully 
during installation and operation of the unit. Read this manual thoroughly before attempting to unpack, 
install, or operate your UPS. 
CAUTION!

 T

o

 prevent the risk of fire or electric shock, install in a temperature and humidity controlled indoor area 

free of conductive contaminants. (See the specifications for the acceptable temperature and humidity range.) 

CAUTION!

 To reduce the risk of overheating the UPS, do not cover the UPS' cooling vents and avoid exposing the 

unit to direct sunlight or installing the unit near heat emitting appliances such as space heaters or furnaces. 

CAUTION!

 Do not attach non-computer-related items, such as medical equipment, life-support equipment, microwave 

ovens, or vacuum cleaners to UPS. 

CAUTION!

 Do not plug the UPS input into its own output. 

CAUTION!

 Do not allow liquids or any foreign object to enter the UPS. Do not place beverages or any other 

liquid-containing vessels on or near the unit. 

CAUTION!

 In the event of an emergency, press the OFF button and disconnect the power cord from the AC power 

supply to properly disable the UPS. 

CAUTION!

 Do not attach a power strip or surge suppressor to the UPS. 

CAUTION!

 Unplug the UPS prior to cleaning and do not use liquid or spray detergent. 

 

   

 

 

 

INSTALLING YOUR UPS SYSTEM

 

 

UNPACKING 

The box should contain the following: 
(1)UPS Unit 1; (2)User Manual 1; 

HOW TO DETERMINE THE POWER REQUIREMENTS OF YOUR EQUIPMENT 

1. 

Ensure that the equipment plugged into the battery power-supplied outlets does not exceed the UPS unit

’s 

rated capacity. If rated unit capacities are exceeded, an overload condition may occur and cause the UPS 
unit to shut down or the fuse blow. 

2. 

There are many factors that can affect the amount of power that your computer system will require. For 
optimal system performance keep the load below 80% of the unit

’s rated capacity. 

HARDWARE INSTALLATION GUIDE 

1. 

Your new UPS may be used immediately upon receipt. However, recharging the battery for at least 8 hours is 
recommended  to  ensure  that  the  battery's  maximum  charge  capacity  is  achieved.  Charge  loss  may  occur 
during shipping and storage. To recharge the battery, simply leave the unit plugged into an AC outlet. The unit 
will charge in both the on and off position. 

2. 

With the UPS unit off and unplugged, connect the computer, monitor, and any externally powered data storage 
device. 

3. 

Plug the UPS into a 2 pole, 3 wire grounded receptacle (wall outlet). Make sure the wall branch outlet is 
protected by a fuse or circuit breaker and does not service equipment with large electrical demands. 

4. 

Depress the power switch to turn the unit on. The LCD indicator light will illuminate and the unit will "beep". 

5. 

To maintain optimal battery charge, leave the UPS plugged into an AC outlet at all times. 

6. 

To store your UPS for an extended period, cover it and store with the battery fully charged. Recharge the 
battery every three months to ensure battery life. 

 
 
 
 

Summary of Contents for KI 1000R 1U

Page 1: ...KI 1000R 1U 1000VA Line Interactive Sinewave UPS Version USER MANUAL ...

Page 2: ...EM UNPACKING The box should contain the following 1 UPS Unit 1 2 User Manual 1 HOW TO DETERMINE THE POWER REQUIREMENTS OF YOUR EQUIPMENT 1 Ensure that the equipment plugged into the battery power supplied outlets does not exceed the UPS unit s rated capacity If rated unit capacities are exceeded an overload condition may occur and cause the UPS unit to shut down or the fuse blow 2 There are many f...

Page 3: ...For extended storage in moderate climates the battery should be charged for 12 hours every 3 months by plugging the power cord into the wall receptacle and turning on the main switch Repeat it every 2 months in high temperature locations BASIC OPERATION FRONT AND TOP PANEL DESCRIPTION 1000 1500 R1U 1 AC Inlet Connect to utility power through the input power cord 2 Input Circuit Fuse The fuse provi...

Page 4: ...the UPS ON or OFF 10 Mute Button The audible alarm can be turned off on by pressing this button SOFTWARE DOWNLOAD Power Master management software provides a user friendly interface for your power systems The graphic user interface is intuitive and displays essential power information at a glance Please follow procedure below to install the software Installation procedure 1 Download Power Master f...

Page 5: ...ansfer Time AC to Battery 5ms typical 10ms max Charger 1A Protection Overload protection on utility fuse on battery internal current limiting Efficiency LINE mode full Load 95 0 Batteries and autonomy time Batteries 4x 6V 7 Ah DC Voltage 24 V Recharge Time 8h to 90 Connections and communication IEC 320 C13 Outlet 4 Input IEC 320 C14 Software Power Master USB port HID Support Yes RS 232 Port Extens...

Page 6: ...DEFINITIONS FOR ILLUMINATED LCD INDICATORS LCD indication Line Battery Mode ALARM DEFINITIONS ...

Page 7: ...TROUBLE SHOOTING ...