ROUTINE MAINTENANCE AND STORAGE
ROUTINE MAINTENANCE
1.
Use dry soft clothes to clean the front panel and plastic parts. Do not use any detergent that contains alcoholic
ingredient.
2.
The expected lifetime of the battery is around 3 years. Improper operation and harsh environment will reduce the
actual lifetime.
3.
Unplug the UPS from power inlet if the UPS will not operate for long period of time.
STORAGE
1.
First turn off your UPS and disconnect its power cord from the wall outlet. Disconnect all cables connected the
UPS to avoid
battery drain.
2.
The UPS should be stored in a cool dry location.
3.
Make sure the battery is fully charged before the UPS is stored.
4.
For extended storage in moderate climates, the battery should be charged for 12 hours every 3 months
by plugging the power cord into the wall receptacle and turning on the main switch. Repeat it every 2
months in high temperature locations.
BASIC OPERATION
FRONT AND TOP PANEL DESCRIPTION
1000/1500 R1U
1.
AC Inlet
Connect to utility power through the input power cord.
2.
Input Circuit Fuse
The fuse provides optimal overload protection.
3.
AC outlet
The UPS provides outlets for connected equipment to insure temporary uninterrupted operation during a power
failure and against surges and spikes.
4.
SNMP/HTTP Network Port
The SNMP/HTTP port provides remote monitoring and management of your UPS over a network.
5.
Serial Port
This port allows connection and communication from the DB9 serial on the computer to the UPS unit. The
UPS communicates its status to the software.