background image

 

1

 

www.fiduspower.com

  

 

MVPS1000 

Series

  

 

Model Number 

 

Output Power

(1)  

 

Output Voltage 

 

Output Current        

 

MVPS1000

-

1012

 

500W

 

12V

 

41.67A

 

MVPS1000

-

1015

 

625W

 

15V

 

41.67A

 

MVPS1000

-

1024

 

1000W

 

24V

 

41.67A

 

MVPS1000

-

1030

 

1000W

 

30V

 

 33.33A

 

MVPS1000

-

1048

 

1000W

 

48V

 

 20.83A

 

MVPS1000

-

1058

 

1000W

 

58V

 

 17.24A

 

Models & Ratings

 

Dimensions:

 

5 x 9.51 x 

1.61” (127 

x 241.6 x 40.9mm)

 

Parameter

 

Minimum

 

Typical

 

Maximum

 

Units

 

Notes & Conditions

 

AC Input range

 

85

 

 

264

 

VAC

 

Derate from 100% at 120VAC to 70% at 85VAC

 

Operating temperature

 

-

40

 

 

70

 

°C

 

See derating curve p3. 

 

Efficiency

 

120VAC 88% and 240VAC 93% typical

 

Dimensions

 

5 x 9.51 x 

1.61” (127 

x 241.6 x 40.9mm)

 

EMC

 

EN55011 Level B conducted and radiated with king core K5B RC 25x12x15

-

M on input.  EN61000

-

3 and EN61000

-

4, harmonics, 

flicker, Surge, EFT, ESD, conducted and radiated, IEC60601

-

1

-

2 4th ed

 

Safety

 

EN60601

-

1, IEC60601

-

1 (ed3), ANSI/AMMI ES 60601

-

1, CSA C22.2 No 60601

-

1

 

Key specifications

 

• 

5 x 

9.51” 

Footprint, 

1.61” 

for 1U installation 

 

• 

Medical approvals; IEC60601

-

1 3.1, BF rated, IE60601

-

1

-

2 4th ed

 

• 

Up to 3 units load share for higher powers 

 

• 

+/

-

3% Output voltage adjust

 

• 

EN55011 Level B conducted & radiated

 

• 

3 Year warranty

 

 

1000 Watts

 

The MVPS1000 series of low profile, medical grade AC

-

DC power modules offer 500

-

1000W in a 

5” 

9.51” 

package conforming to the latest IEC60601

-

1 (3.1), IEC60601

-

1

-

2 4th ed standards. The units 

are fully featured including 5V 1.5A auxiliary output, low standby power of 3W and are suitable for 
body floating applications. They have a wide operating temperature of –

40 

to 70°C, in a range of   

voltages from 12V to 58V. All units come with a FiDUS 3 year warranty.

 

Notes  

 

INSTALLATION ADVICE PG6

 

1.  Combined output power is main DC  fan output 12V / 500mA max

 

Summary of Contents for MVPS1000 Series

Page 1: ...ker Surge EFT ESD conducted and radiated IEC60601 1 2 4th ed Safety EN60601 1 IEC60601 1 ed3 ANSI AMMI ES 60601 1 CSA C22 2 No 60601 1 Key specifications 5 x 9 51 Footprint 1 61 for 1U installation Medical approvals IEC60601 1 3 1 BF rated IE60601 1 2 4th ed Up to 3 units load share for higher powers 3 Output voltage adjust EN55011 Level B conducted radiated 3 Year warranty 1000 Watts The MVPS1000...

Page 2: ...AC 88 and 240VAC 93 typical Isolation Input to Output 4245 VAC Input to Ground 1625 VAC Output to ground 1500 VAC Switching frequency 85 100 kHz 100 kHz variable for power switching Variable PFC switching 85kHz Power density 12 73 W In3 MTBF 1 28 MHrs As per Telcordia SR332 issue 3 Weight 1300 g General Parameter Minimum Typical Maximum Units Notes Conditions Operating temperature 40 70 C Please s...

Page 3: ...Fields EN61000 4 8 3 A 10A M Voltage Dips and Interruptions EN61000 4 11 A B EMC Immunity Safety standard Notes Conditions UL CSA AMMI ANSI ES 60601 1 R 2012 CAN CSA C22 2 NO 60601 1 14 UL Certificate No 20190221 E173812 CB IEC60601 1 2005 A1 2012 CB Test Certificate No NO105338 Nemko EN60601 1 2006 A1 2012 Nemko Certificate No P19223365 CE 2011 65 EU RoHS Directive and 2014 35 EU Low voltage dire...

Page 4: ...t share will not function When using the load share function derate the cumulative power total by 10 Please follow the below step by step process to ensure smooth operation Connect all output cables to Vout Connect all Vs cables and twist pairs together Terminate all the Vs lines to the same points Connect the load share LS pin 10 on J3 of all the units With other units tuned off on each PSU use t...

Page 5: ... J2 Output connector 6 32 pan screw Can accept AMP 8 31886 1 Tongue 11A max AWG16 J3 I O Connector 4 Pin Connections Pin Function 1 GND 2 5V 1 5A 3 PGPF 4 VS 5 VS 6 GND 7 Remote on off 8 Current limit p2 9 Current limit p1 10 Load share ULP275 Series WLP350 Series 4 J3 I O header Molex 22 23 2101 mating part Molex 22 01 2107 MVPS1000 Series J1 Input Connector 2 Pin Connections Pin Function 1 Line ...

Page 6: ...llations but on some power supplies there may be additional earth tags or mounting points 2 Minimise the length of input output wiring where possible and try to maintain max distance of the conductors from the PSU to prevent noise pick up Avoid bundling input and output cables together A common component to avoid placing wiring near is the PFC inductor in power factor corrected power supplies 3 Ap...

Reviews: