Hydro Logger H1
User manual
44
electronics for ecology
FIEDLER
TIME ZONE
By ticking the "
Automatically change to daylight saving time
" option, you allow
the device to automatically adjust its internal functions during the time change,
for example, to send regular text messages. This means that an informative SMS
message will be sent automatically at a fixed time throughout the year - for
example, every Monday at 8:00 am.
The data will always be recorded in the station's memory according to standard
time, regardless of the parameter selection. This is so that the time sequence of
the measured values is not disturbed.
The setting of this parameter affects the calculation of daily leakage volumes,
daily precipitation, etc. The parameter is used for example when loading data in
an organization using shift operation, where the calculation needs to start with
the start of a new shift (e.g. at 6:00).
ARCHIVING
This parameter can be set from 1 minute to 1440 minutes (1 day) and determi-
nes the frequency with which the instrument will wake up and measure the set
measurement channels. Typical current consumption of a switched on station
without GSM modem on with one 4-20 mA sensor is around 30 mA. Between
measurements, the microprocessor and with it the whole station is put into a
very low power consumption mode (20 uA).
Individual measurement channels can have their own "
Archiving Interval"
set
differently, which must be a multiple of this basic recording interval. The
average of as many measurements as the basic archiving interval fits within the
archiving interval of the recording channel is then stored in memory.
Station H1 automatically sets the time of the first recording so that, regardless
of the set archiving interval, the recording occurs at the full hour. For example,
if the "Archiving Interval" is set to 10 minutes and the station starts measuring
at the 13th minute of the current hour, the first memory entry will take place at
the 30th minute and regularly every 10 minutes thereafter. Thus, the station
will not store data at the 23rd, 33rd, 43rd, etc. minute.
The name of this option implies its meaning. Checking it allows to store extraor-
dinary and unexpected conditions in the event memory, which can be, for
example, disconnection of the measuring sensor, error signal of the intelligent
probe, etc.
Checking this option allows you to store information about sent SMS messages
in the data memory. In addition to the sending time, the text of the sent
message and the recipient's phone number are also recorded.
Note:
The event memory is automatically loaded along with the reading of the
data memory and its contents are stored in a file with the *.dte extension. The
file name under the asterisk is the same as the measured data file name. When
using the server for data acquisition, the event table is displayed last in the
"GRAPH" section.
Similar to the previous choice. The checkbox enables storing the exact time of
SMS messages receipt including their text and sender identification (his/her
phone number) in the event memory.
S u m m e r t i m e
S t a r t o f t h e d a y
B a s i c a r c h i v i n g
i n t e r v a l
D a t a a v e r a g i n g f o r
a r c h i v i n g
F a u l t a n d
e m e r g e n c y
c o n d i t i o n s
S e n t m e s s a g e s
M e s s a g e s
r e c e i v e d
Summary of Contents for H1
Page 1: ...Small telemetry station for water applications H1 H2 Hydro Logger user manual version 1 10 ...
Page 2: ...Hydro Logger H1 User manual 2 electronics for ecology FIEDLER ...
Page 80: ...Hydro Logger H1 User manual 80 electronics for ecology FIEDLER Notes ...
Page 81: ...Hydro Logger H1 User manual FIEDLER electronics for ecology 81 ...