COMBUSTION AIR SYSTEM  

Model:

 CAS-6, CAS-6SK, CAS-7, and CAS-7SK 

This product is designed for use with any oil or gas fired furnace, water heater, or 
boiler with 24 VAC or 120 VAC control systems. It may also be used with millivolt 
water heaters and more than one appliance. The CAS unit mechanically draws air 
into a structure and disperses it near the combustion air intake of an appliance. 
Refer to Diagrams A & B for guidance in setting up the CAS system based on the 
size and length of the connecting duct-work and the input rating of the appliance. 

 

 

This device MUST be installed by a qualified agency in accordance with the manufacturers installation 
instructions.

  

The definition of a qualified agency is: 

any individual, firm, corporation or company which either in person or through a 

representative is engaged in, and is responsible for, the installation and operation of gas appliances, who is experienced 
in such work, familiar with all the precautions required, and has complied with the requirements of the authority having 
jurisdiction.

 

 

 

DO NOT DESTROY 

THESE INSTRUCTIONS MUST REMAIN WITH EQUIPMENT 

 
 

  

I

TEMS 

I

NCLUDED

 

1)   CAS unit (ETL Listed)  

“Fan-in-a-Drum” 

1)   Star Kap (only on SK   

 Models) 

2)   Mounting brackets for  

 CAS  unit 

  2)   Wire/conduit connector(s) 

1)  24VAC Control Relay 

 (SPDT) 

1) 120VAC 

Control 

Relay 

(SPDT)

 

2630 Airport Road Kinston, NC 28504 

Phone: 252-522-3031  FAX: 252-522-0214 

ww.fieldcontrols.com

 

Summary of Contents for 46371700

Page 1: ...gency in accordance with the manufacturers installation instructions The definition of a qualified agency is any individual firm corporation or company which either in person or through a representati...

Page 2: ...ng the horizontal axis and draw a vertical line through this point 5 The line should pass through at least one of the pipe size regions on the table The regions correspond to the maximum equivalent le...

Page 3: ...IPE 6 PIPE 8 PIPE 6 DUCT REGION 8 DUCT REGION 10 DUCT REGION 12 DUCT REGION Diagram A DIAGRAM B CAS 7 FAN STARKAP SK 12 SIZING CHART MAX EQUIVALENT FEET OF PIPE 0 0 25 0 50 0 75 0 100 0 125 0 150 0 17...

Page 4: ...9 424 1057 5 700 000 121 369 919 5 25 735 000 105 321 800 5 75 805 000 79 241 601 6 840 000 58 176 519 6 5 910 000 49 151 377 CAS 7 OIL gph CAS 7 GAS BTU hr 10 duct 12 duct 14 duct 6 840 000 469 1167...

Page 5: ...g pipe of different diameter than the CAS component connections attach increaser reducer fittings as close to the CAS unit and to the StarKap as possible The duct should be supported with appropriate...

Page 6: ...AS unit Refer to Figure 6 for connecting a single 120 VAC appliance to the CAS or Figure 7 for 24 VAC The three wires BURNER WHITE and ORANGE in Figure 4 correspond to the same wires shown in Figures...

Page 7: ...Figure 7 Figure 8 Page 7...

Page 8: ...Figure 9 Figure 10 Page 8...

Page 9: ...Figure 11 Figure 12 Page 9...

Page 10: ...ly CAUTION A minimum clearance of 1 must be maintained between the bottom of the fan blade and the top of the metal surface underneath FAILURE TO MAINTAIN THIS CLEARANCE MAY RESULT IN A FIRE HAZARD AN...

Page 11: ...Page 11...

Page 12: ...Page 12 P N 46371700 Rev B 06 06...

Reviews: