Please retain these instructions after installation.

This  device  MUST  be  installed  by  a  qualifi ed  agency  in  accordance  with  the  manufacturer's  installation  instructions.  The  defi nition of 
a qualifi ed agency is: any individual, fi rm, corporation or company which either in person or through a representative is engaged 
in, and is responsible for, the installation and operation of HVAC appliances, who is experienced in such work, familiar with all the 
precautions required, and has complied with all the requirements of the authority having jurisdiction.

READ THESE INSTRUCTIONS CAREFULLY AND COMPLETELY BEFORE PROCEEDING WITH THE INSTALLATION.

Installation Date:

Installed By:

Phone:

COMBUSTION AIR SYSTEM

MODEL: CAS-4

This product is designed for use with any natural gas or LP burning furnace, water heater, or boiler with a 24 
VAC control system. The CAS-4 may be used with one 24V-controlled combustion heating appliance and one 
30mV standing-pilot gas water heater with the use of an additional CK-20 series control kit.  Additional 120V or 
24V-controlled appliances may also be served by the CAS-4 with the addition of one CAC-120 or CAC-24 control 
kit per each additional appliance (see note)*. The CAS unit mechanically draws air into a structure and disperses it
near the combustion air intake of an appliance. Refer to Diagrams A and B for guidance in setting up the CAS 
system based on the size and length of the connecting ductwork and the input rating of the appliance.

ITEMS INCLUDED IN KIT:
1- Motorized Blower 

 

 

 

 

 

1- 4" galvanized intake air Vent Hood

2- Mounting brackets to secure the CAS to a wall 

 

2- Wire/conduit connectors

1- 4" x 6" Pipe Increaser Fitting   

 

 

 

1- 6" Orifi ce Ring

1- Instruction Sheet 

 

 

 

 

 

1- High/Low Motor Speed Switch

P/N 46284600 Rev L 09/19

WARNING!  CONNECTIONS  TO  MULTIPLE  APPLIANCES  MUST  FOLLOW  INSTALLATION  INSTRUCTION 

WARNING! CONNECTIONS TO MULTIPLE APPLIANCES MUST FOLLOW INSTALLATION INSTRUCTION 
WIRING DIAGRAMS. FOR HELP CALL 1-800-742-8368.

WIRING DIAGRAMS. FOR HELP CALL 1-800-742-8368.

*NOTE:  The model CAS-4 design has recently been changed.  Please note that there are diff erences in construction, 
operation,  and  installation  of  this  CAS  as  compared  to  legacy  product.    Also,  note  that  for  multiple-appliance 
installations, each additional appliance will require either a CAC-24 or CAC-120 control kit be provided for that 
appliance. Installations with one heating appliance and one 30mV gas water heater will require an additional CK-20 
series control kit in addition to the CAS-4.

Summary of Contents for FAN IN A CAN CAS4

Page 1: ...24 control kit per each additional appliance see note The CAS unit mechanically draws air into a structure and disperses it near the combustion air intake of an appliance Refer to Diagrams A and B fo...

Page 2: ...l within one of the three regions on the table Each region corresponds to a duct pipe diameter of 4 4 using the orifice ring and 6 respectively GENERAL SYSTEM OPERATION 1 The thermostat wall thermosta...

Page 3: ...matter which way the Orifice Ring is turned as long as it is pushed down against the ledge completely Use 4 diameter pipe to connect the vent hood and the CAS unit TOTAL INPUT OF APPLIANCE TOTAL INPU...

Page 4: ...00 250 300 350 400 GAS INPUT FIRING RATE 1000 BTU hr MAX EQUIVALENT DUCT LENGTH ft 0 0 0 50 1 00 1 50 2 00 2 50 OIL INPUT FIRING RATE gallons per hour 1 gallon oil hr 140 000 BTU hr 6 Duct Hood 4 Duct...

Page 5: ...a power vented exhaust outlet and should be on the same wall The intake air hood should be a minimum of 1 above grade or snowlines where applicable INSTALLATION OF INTAKE AIR HOOD After determining t...

Page 6: ...be attached to the green colored ground screw near the wire terminals The following sections describe the most common applications The references to various series of control kits implies that any ki...

Page 7: ...page 7 of 12 Figure 5 Power Vent Single 24V Furnace Figure 6 Chimney Vent 24V Furnace and 30mV Water Heater With CK 20FV or CK 20FG P N 46284600 Rev L 09 19...

Page 8: ...page 8 of 12 Figure 7 Chimney Vent 24V Boiler Figure 8 Power Vent Single 24V Boiler P N 46284600 Rev L 09 19...

Page 9: ...page 9 of 12 Figure 9 Chimney Vent Two 24V Gas Appliances With CAC 24 P N 46284600 Rev L 09 19...

Page 10: ...page 10 of 12 Figure 10 One Power Venter Two 24V Gas Appliances P N 46284600 Rev L 09 19...

Page 11: ...nadequate air flow is allowed into the inlet of the CAS 4 Clear any obstructions if present from the inlet of the vent hood and the outlet of the CAS unit 5 Periodically the fan blade chamber may need...

Page 12: ...ed and printed from the Field Controls website www fieldcontrols com WARRANTY WARRANTY For warranty information about this or any Field Controls product visit For warranty information about this or an...