background image

EN

 

  

5

 

INSTRUCTION MANUAL

FDAK 12011

Tires:

Push the valve lever connector onto the valve and close by moving the lever 

downward.

Connect the power supply cable plug to the cigar lighter socket and turn the 
ON/OFF switch to ON.
On reaching the required pressure remove the valve lever connector from the 

valve spindle and disconnect the 12V plug from the socket.

Inflatables:

Select a matching adapter and attach to the valve lever connector .Close the 

connector.

Insert the adapter into the item to be inflated.

Connect the power supply cable plug to the cigar lighter socket and turn the 

ON/OFF switch to ON

On reaching the required pressure remove the valve lever connector from the 

inflated item and disconnect the 12V plug from the socket.

This compressor is not designed for long continuous operation. With excessively 

long operation the compressor will be overheated and will be damaged. If 

operated carelessly or if the external metal parts become hot (detectable by 

touch), it means that the compressor has been switched on for too long time 

and is overheated. In this case switch off the compressor immediately and 

leave it for to get cool (about 20 minutes) always after 10 minutes of continuous 

operation.

This compressor may also be operated from a 12V battery charger. However to 

avoid damage to compressor and charger 10 Amp or more are required.

TROUBLESHOOTING:

Compressor does not start /fuse blows:

Plug can be inserted deeply into the hole and can be turned in either direction.

Remove dirt from hole and plug. Use a non-conducting probe, never metal or 

fingers.

Check cigar lighter fuse. Minimum capacity 10 Amp. Plug disconnected

.Compressor runs but does not inflate:

Connector –with dosed lever –should sit tightly in the valve.

Check the item to be inflated for leaks.  Check hose and connections for 

cracks and leaks

Compressor works too slowly:

Overheating after excessively long operation. Disconnect plug and leave to 

cool for 20 minutes.
Voltage too low. Check battery.

1. Switch ON/OFF

2. Pressure Gauge

3.Supply Lead (Power Cord)

4. Adaptors

5.Air Output Hose

Summary of Contents for FDAK 12011

Page 1: ...FDAK 12011...

Page 2: ...2 English e tina Sloven ina Magyarul Polski 04 06 08 10 12 14...

Page 3: ...3 FDAK 12011 1...

Page 4: ...r yank the hose from an inflation valve DO NOT pull the plug from the cigarette lighter socket using the lead DO NOT get the compressor wet or use in the rain DO NOT use the compressor for a task that...

Page 5: ...l metal parts become hot detectable by touch it means that the compressor has been switched on for too long time and is overheated In this case switch off the compressor immediately and leave it for t...

Page 6: ...NENECH VEJTE kompresor b hem provozu bez dozoru M jte kompresor st le pod dohledem a sledujte tlak vzduchu NEP EN EJTE kompresor za hadici a hadici nestrh vejte z ventilku NEVYTAHUJTE z str ku ze z su...

Page 7: ...V takov m p pad kompresor ihned vypn te a nechte vychladnout asi 20 minut stejn postupujte v dy po 10 minut ch nep etr it ho provozu Kompresor je tak mo n nap jet pomoc nab je ky 12 V bateri Aby se v...

Page 8: ...as prev dzky bez dozoru Majte kompresor st le pod doh adom a sledujte tlak vzduchu NEPREN AJTE kompresor za hadicu a hadicu nestrh vajte z ventil eka NEVY AHUJTE z str ku zo z suvky pre zapa ova ahom...

Page 9: ...hriaty V takom pr pade kompresor ihne vypnite a nechajte vychladn asi 20 min t rovnako postupujte v dy po 10 min tach nepretr itej prev dzky Kompresor je tie mo n nap ja pomocou nab ja ky 12 V bat ri...

Page 10: ...d s k zben Mindig figyelje alatt a kompresszort s k vesse figyelemmel a leveg nyom s t NE HELYEZZE T a kompresszort a t ml n l fogva s a t ml t ne h zza ki a szelepb l NE H ZZA KI a csatlakoz t a szi...

Page 11: ...al kapcsolja ki a kompresszort s hagyja kih lni kb 20 perc ugyan gy j rjon el minden 10 percnyi folyamatos m k d s ut n A kompresszort 12 V akkumul tort lt vel is zemeltetni lehet Hogy azonban se a ko...

Page 12: ...ora bez nadzoru Miej kompresor stale pod nadzorem i kontroluj ci nienie powietrza NIE PRZENO kompresora za przew d i nie ci gaj przewodu z wentyla NIE WYCI GAJ wtyczki z gniazdka na zapalniczk za kabe...

Page 13: ...do wystygni cia oko o 20 minut podobnie post puj zawsze po 10 minutach nieprzerwanego u ytkowania Kompresor mo na tak e adowa przy pomocy adowarki baterii 12 V Aby kompresor lub adowarka nie zosta y...

Page 14: ...14 12 RU 12 12 14 20 80 3 1 2 6 87 PSI 0 1 12...

Page 15: ...RU 15 FDAK 12011 12 12 20 10 12 10 10 20 1 2 3 4 5...

Page 16: ......

Reviews: