Functions

Weight Measurement

Your SR47 scale is designed to measure 

refrigerant tanks weighing up to 252 lbs. 

 

Placing items over 252 lbs on the scale may 
damage the scale.

1  Remove the scale from the padded case and 

place the platform on solid, level ground.

2  Press   for 1 second to turn on the platform.
3 Press   for 1 second to turn on the display.
4  Press ZERO for 1 second to zero out the scale.   
5 Set your tank on the platform and press 

TARE for 1 second to view only the change 
in refrigerant.

6  View the change in weight in real-time when 

charging or recovering refrigerant.

Backlight

Tap 

 to turn on the blue backlight on the 

LCD. This is useful when the sun is going down 
on late day jobs or any dark situation. The back-
light uses extra battery power than standard 
use.

Auto Power Off (APO)

If the weight is unchanged for 30 minutes, 

the platform will automatically power off. 

To disable APO, while power is on tap   twice 

on the platform. The LED will briefly blink red 
and APO will not be shown on the display.

To enable APO,  while power is on tap   twice 

on the platform. The LED will briefly shine red 
and APO will be shown on the display.

Syncing a Display to a Platform

The included remote display is setup to view 

the platform at the factory. You shouldn't ever 
need to re-sync them. You can sync two SR47 
remote displays to a single SR47 platform if 
desired. 
1  Press and hold UNITS button for 1 second. 
2 The ID# of a detected platform will show. 

(This ID# is printed on the platform.)

3  Tap UNITS button  to cycle through any other 

platforms detected.

4  Press and hold UNITS button for 1 second to 

select a platform.

Using the Job Link® system app and SMAN 

digital manifold as a display:

  

Link the SR47 to app or manifold to use as display.

Tech Tips 

Respect the Environment

Always use hoses with ball valves or low-loss 

fittings to minimize harmful refrigerant gases 
entering the atmosphere.

Account for Your Hose Weight

Connect the hoses to the system and tank 

before zeroing the scale. After charge/recovery 
is finished and the system is stable, note the 
weight before removing hoses.

Use your Appropriate G-Value

Acceleration due to gravity in m/s2 (G-Value)

varies slightly depending on your altitude and 
location. Here are few cities' examples:

Los Angeles (default) 9.796
New York City  

9.802

Paris 

 

  9.809

Sydney  

 

9.797

Denver  

 

9.798

  

 1 Hold UNITS while powering on display.                   
 2 With the current G-Value showing, tap TARE  
    and         to scroll up and down respectively.     
 3 Tap UNITS to save and exit.

Limited Warranty

This scale is warranted against defects in material or workman-

ship for one year from date of purchase from an authorized Fieldpiece 
dealer. Fieldpiece will replace or repair the defective unit, at its option, 
subject to verification of the defect.

This warranty does not apply to defects resulting from abuse, 

neglect, accident, unauthorized repair, alteration, or unreasonable use 
of the instrument.

Any implied warranties arising from the sale of a Fieldpiece prod-

uct, including but not limited to implied warranties of merchantability 
and fitness for a particular purpose, are limited to the above. Fieldpiece 
shall not be liable for loss of use of the instrument or other incidental or 
consequential damages, expenses, or economic loss, or for any claim of 
such damage, expenses, or economic loss. 

State laws vary. The above limitations or exclusions may not apply 

to you.

Obtaining Service

For international customers, warranty for products purchased out-

side of the U.S. should be handled through local distributors. Visit our 
website to find your local distributor.

© Fieldpiece Instruments, Inc  2022; v02