background image

 

 

 

 

 

 

 

 

 

 

 

Start-up guide 

Page 5 

FS-X20 Series FieldServer Start-up Guide (07-2005) 

2.4.  Supplied Connector Kit (FS-8915-11) 

In  order  to  facilitate  RS-232  communications  on  the  RJ-45  RS-232  port,  a  connector  kit  is  supplied 
containing  one  of  each  of  the  connectors  shown  in  the  diagram  below.    The  tables  in  the  diagram 
show the functions applied to each of the RJ-45 pins by the FieldServer to assist in determination of 
the required pinout configuration for connection to the third party device.  

 

8

1

RJ45

DB9M

FS-8917-03

 

8

1

RJ45

DB9F

FS-8917-02

 

 

 

DB25M

8

1

RJ45

FS-8917-01

 

8

1

RJ45

DB25F

FS-8917-04

 

 

 

Figure 2-4: FieldServer Connector Reference 

 

RX          
CTS

 

DSR

 

GND

 

GND

 

DTR

 

RTS

 

TX

 

RJ45-01

 

RJ45-02

 

RJ45-03

 

RJ45-04

 

RJ45-05

 

RJ45-06

 

RJ45-07

 

RJ45-08

 

DB9M - 02

 

DB9M - 08

 

DB9M - 06

 

DB9M - 05

 

DB9M - 04

 

DB9M - 07

 

DB9M - 03

 

GREY

 

BROWN
YELLOW
GREEN

 

RED

 

BLACK
ORANGE
BLUE

WIRE LIST

X20

 

FUNCTION

 

FROM

DEFAULT

 

COLOR

 

RX          
CTS

 

DSR

 

GND

 

GND

 

DTR

 

RTS

 

TX

 

RJ45-01

 

RJ45-02

 

RJ45-03

 

RJ45-04

 

RJ45-05

 

RJ45-06

 

RJ45-07

 

RJ45-08

 

DB9F - 03

DB9F - 05

DB9F - 02

WHITE
BROWN
YELLOW
GREEN

 

RED

 

BLACK
ORANGE
BLUE

 

WIRE LIST

X20

 

FUNCTION

 

FROM

 

DEFAULT

 

COLOR

 

RX          
CTS
DSR

 

GND
GND
DTR
RTS
TX

 

RJ45-01

 

RJ45-02

 

RJ45-03

 

RJ45-04

 

RJ45-05

 

RJ45-06

 

RJ45-07

 

RJ45-08

 

WIRE LIST

 

X20

 

FUNCTION

 

FROM

 

DB25M - 03

 

DB25M - 05

 

DB25M - 07

 

DB25M - 04

 

DB25M - 02

 

WHITE
BROWN
YELLOW
GREEN

 

RED

 

BLACK
ORANGE
BLUE

DEFAULT

COLOR

 

RX          
CTS

 

DSR

 

GND

 

GND

 

DTR

 

RTS

 

TX

 

RJ45-01

 

RJ45-02

 

RJ45-03

 

RJ45-04

 

RJ45-05

 

RJ45-06

 

RJ45-07

 

RJ45-08

 

WIRE LIST

 

X20

 

FUNCTION

 

FROM

DB25F - 02

 

DB25F - 04

 

DB25F - 07

 

DB25F - 05

 

DB25F - 03

 

DEFAULT

WHITE
BROWN

 

YELLOW

 

GREEN

 

RED

 

BLACK

 

ORANGE

 

BLUE

 

COLOR

Summary of Contents for FS-X20 Series

Page 1: ...888 509 1970 Fax 408 262 2296 Email support fieldserver com Web Site www fieldserver com FS X20 Series FS X20 Start up Guide APPLICABILITY EFFECTIVITY This manual provides instructions for the following FieldServer products Description FS X20 Series FieldServer The instructions are effective for the above as of February 2005 Instruction Manual Part Number T17005 Rev D ...

Page 2: ... 5 3 OPERATION 8 3 1 Install and Run the Utility Software 8 3 2 Use PING to Identify the FieldServer on the Network 8 3 3 Connect using Remote User Interface RUINET 8 3 4 Use RUINET to change the FieldServer IP Address and Network 8 3 5 Upload the Default Configuration 8 3 6 Change the Configuration File to Meet the Application 9 3 7 Download the Updated Configuration File 9 3 8 Test and commissio...

Page 3: ...8915 13 RS 485 connector Part Number FS SPA59137 Set of four different connectors DB9M DB9F DB25M DB25F Part Number FS 8915 11 Power Supply Connector for power SPA59136 1 2 Start up Read this Start up Guide in conjunction with the Configuration Manual the 1 Note that a default configuration file has already been loaded onto the FieldServer Check the Driver Manual and the FieldServer Configuration ...

Page 4: ... the 9 24V 100mA required by the FieldServer during testing and start up Permanent 9 30V 100mA power will need to be provided for continuous operation The FS X20 Series FieldServer is shipped as either a FS X20XX 01 in which case the RS 232 port is activated or as a FS X20XX 02 in which case the RS 485 port is activated If using an RS 232 RJ45 Serial connection then use one of the RJ45 cables to c...

Page 5: ...62 2299 FS X20 OUTLINE DIMENSIONS FieldServer Tech n o lo g ies 408 262 2299 www fieldserver com FIELDSERVER BRIDGE FS B2010 01 Rx Tx Rx Tx Ethernet EIA232 USB EIA485 Power OK FieldBus Active FieldServer 3 82 4 08 1 70 0V INPUT 9 30Vdc 1A OR 24Vac 50 60HZ 1A Class 2 LPS Frame Ground Serial FieldServer Running Hot Standby Active Node Offline Configuration Error Comm Error System Error IP Request Fi...

Page 6: ...RJ45 02 RJ45 03 RJ45 04 RJ45 05 RJ45 06 RJ45 07 RJ45 08 DB9M 02 DB9M 08 DB9M 06 DB9M 05 DB9M 04 DB9M 07 DB9M 03 GREY BROWN YELLOW GREEN RED BLACK ORANGE BLUE WIRE LIST X20 FUNCTION FROM DEFAULT COLOR RX CTS DSR GND GND DTR RTS TX RJ45 01 RJ45 02 RJ45 03 RJ45 04 RJ45 05 RJ45 06 RJ45 07 RJ45 08 DB9F 03 DB9F 05 DB9F 02 WHITE BROWN YELLOW GREEN RED BLACK ORANGE BLUE WIRE LIST X20 FUNCTION FROM DEFAULT...

Page 7: ...ector C 11 Undefined 12 Secondary Rcvd Line Signal Detector C 13 Secondary Clear to Send C 14 Secondary Transmitted Data D 15 Transmitter Sig Element Timing T Timing 16 Secondary Received Data D 17 Receiver Sig Element Timing T 18 Undefined 19 Secondary Request to Send C 20 Data Terminal Ready C 21 Sig Quality Detector C 22 Ring Indicator C 23 Data Sig Rate Detector C 24 Transmitter Sig Element Ti...

Page 8: ...ge 7 FS X20 Series FieldServer Start up Guide 07 2005 FS 8917 16 FS X20 Serial G ORANGE WHITE RJ45 08 BROWN RJ45 01 BLUE WHITE RJ45 04 RJ45 Male Modular Jack Figure 2 8 RS 485 Connection pinouts on the serial RJ45 port ...

Page 9: ...ches the FieldServer This means the first three sections of both IP addresses match Confirm that there is an Ethernet adapter installed in the PC s Device Manager List and that it is configured to run the TCP IP protocol If using Windows XP ensure that the firewall is disabled 3 3 Connect using Remote User Interface RUINET Browse to the Remote User Interface icon in the Start menu directory and cl...

Page 10: ...d that the correct file names are specified Type D to send the file to the FieldServer The utility will display a menu showing download progress Note Wait until the utility indicates that download is complete before resetting the FieldServer or you could corrupt the FieldServer Once download is complete type Esc to get back to the main menu and use the option or simply cycle power to the FieldServ...

Page 11: ...tion or application or on which original identification marks have been removed or altered This Limited Warranty also will not apply to interconnecting cables or wires consumables or to any damage resulting from battery leakage In all cases FieldServer Technology s responsibility and liability under this warranty shall be limited to the cost of the equipment The purchaser must obtain shipping inst...

Page 12: ...t it may take a while from power up to booting up the FieldServer if the loaded configuration is particularly large The light indicates that the FieldServer firmware is running Configuration Error A steady amber light will indicate a configuration error exists in the active configuration See the Error Screen in the Remote User Interface for a description of the configuration error Comm Error A ste...

Page 13: ...Start up guide Page 12 FS X20 Series FieldServer Start up Guide 07 2005 THIS PAGE INTENTIONALLY LEFT BLANK ...

Reviews: