FLSC GB
186
Betriebsanleitung
•
73734 Esslingen - Fiessler Elektronik - Kastellstr.9
•
Doku Nr. 625 R.H.
Properties
Data
min.
type
max.
Measuring error
≤
2 m range
± 94 mm
Measuring error
≤
4 m range
± 131 mm
General data
Electrical connection
Plug-in connector housing,
threaded for 0.5 mm
2
crimp connection, PG 9
Interface
Universal (RS 232 / RS 422)
If you are terminating the cables your-
self, take care to connect the cable
screening. We recommend connecting
the screening at both ends if using
an RS232 connection.
If using an RS422 connection, the
screening should be connected at one
end only. The screening should be
installed at the computer end
(or at the LSI end).
Transfer rate
RS 232
9600 baud
56 kbaud
RS 422
9600 baud
500 kbaud
continuous computer link only
permissible with RS 422
Cable length
RS
232
15
m
RS
422
100
m
Scan rate
2
16
Restart after n seconds
2
60
Laser protection class
1