6. Tests
6.1 Testing the FLSC
These tests are required in order to check that the safety devices are functioning correctly and are
properly incorporated into the machine/system control, as well as to reveal any alterations or
manipulations in the system.
The following instructions must be observed to ensure proper use:
Installation and electrical connection by specialist personnel only.
A specialist is a person who, on account of his specialist training and experience, has sufficient
expertise in the field of the power-driven machinery to be tested, and who is sufficiently familiar with
the pertinent legal work-safety regulations, accident-prevention regulations, directives and generally
recognized engineering rules (e.g. DIN standards, VDE specifications, technical rules of other EC
member states) to be able assess the safe condition of the power-driven machinery. These will
generally be specialists employed by the manufacturer of the NCSD, or such persons who have
received appropriate training from the manufacturer of the NCSD, have been primarily concerned with
the testing of NCSDs and are designated by the owner of the NCSD.
1. Testing prior to first commissioning of the safety
device on the machinery by specialist personnel:
-
Testing prior to first commissioning serves to verify compliance with the safety requirements of the
national / international regulations, and in particular the Machine or Machinery Usage Directive (EC
Declaration of Conformity).
-
Testing of the effectiveness of the safety device on the machine in all operating modes that can be set
on the machine in accordance with the enclosed checklist.
-
The operating personnel of the machine protected by the safety device must receive instruction from
specialists working for the machinery owner before commencing work on the machine. It is incumbent
upon the machinery owner to provide appropriate instruction.
Check your FLSC system by following the checklist printed in chapter 6.2.
2. Regular testing of the safety device by specialist
personnel:
-
Testing in accordance with the pertinent national regulations at the intervals specified therein. These
tests serve to reveal alterations or manipulations to the safety device, which may have been made
since first commissioning.
-
The tests are also to be performed after any substantial modifications to the machine or to the safety
device, and after conversion or repair work in the case of damage to the housing, front screen,
connecting cable etc.
Check your FLSC system by following the checklist printed in chapter 6.2.