System configuration
You can make the following settings for the system:
Current number of persons
Correction of the current number of visitors.
Start value for number of
people after restart
Set as start value after a voltage reset. For example, you can Deduct your staff from
the maximum number of people.
Maximum number of per-
sons allowed
When the maximum number of people is reached, the traffic light switches to red.
Difference to the maximum
number of persons for re-
activation
Set this value if it is desired that after reaching the maximum a certain number of
people must leave the area again before the traffic light switches back to green
Number of persons less than
0 allowed
If this option is active, the current person count is also decremented below 0.
Number of persons greater
'Maximum number of per-
sons' allowed
If this option is active, the current person count is also incremented by the value
'Maximum number of persons' .
Acoustic alarm if the per-
missible number of persons
is exceeded
When this option is active, an audible warning is issued when an access is crossed
when the maximum number of people has already been reached
Error tolerance time Adjust-
ment alarm in seconds
If the counting light barrier is interrupted, this time is maintained until an adjustment
alarm is triggered.
Fault tolerance time Slave
communication in seconds
If a connected and active device does not log to the main column, this time is waited
until a communication alarm is triggered. This time is irrelevant if you use the device
as a single device.
Fault tolerance time for
external components in
seconds
If an event for an actuator cannot be sent for the set time, this is displayed in the actu-
ators overview.
Error message type
Determines whether the warning should only be carried out visually via the traffic
Summary of Contents for RAZL-2
Page 1: ...Inhaltsverzeichnis Deutsch 2 English 34 Français 66 Italiano 98 Español 130 ...
Page 13: ...l Um die geänderten Einstellungen zu übernehmen betätigen Sie das Feld Speichern ...
Page 46: ...l To accept the changed settings click on the Save field ...
Page 53: ...l Click the button to change the current status Deactivate device Activate device ...
Page 78: ...l Pour appliquer les paramètres modifiés appuyez sur la zone Enregistrer ...
Page 110: ...l Per applicare le impostazioni modificate premere la casella Salva ...
Page 142: ...l Para aplicar los ajustes modificados pulse el cuadro Guardar ...
Page 149: ...l Para cambiar el estado actual pulse el botón Desactivar dispositivo Activar dispositivo ...