NATURAL GAS MODELS
:
• Never use with propane, or
any other gases
.
• The appliance and its individual shut-off valve must be disconnected from the
gas supply piping during any pressure testing of the system at test pressure in
excess of 1/2 p.s.i. (3.5 kPa).
• The appliance must be isolated from the gas supply piping system by closing
its individual manual shut-off valve during any pressure testing of the gas
supply piping system at pressures equal to or less than 1/2 p.s.i. (3.5 kPa).
• The gas supply hose must be a minimum of 10 ft (3.1 m) and a maximum of
12 ft (3.6 m). Always disconnect hose at quick connect coupling when storing
your grill.
• Inspect and clean quick connect coupling, and keep it protected when it’s not in
use.
Failure to ensure the above may result in a hazardous fire or
explosion causing serious bodily injury and/or property damage.
To keep your grill working at its peak efficiency as well as contribute to the safe operation
of this unit, perform all of the operations below at least once a year -- preferably at the
start of each cooking season.
PERFORM A LEAK TEST
A leak test ensures that there are no gas leaks prior to lighting your grill.
WHEN A LEAK TEST MUST BE PERFORMED:
• Before lighting your grill for the first time.
• Every time the propane cylinder is refilled
• If any gas component is changed
• At a minimum once per season.
• After prolonged period of storage or non-use.
• If the regulator flow-limiting device has been activated.
The leak test should be performed in a well-ventilated area away from any open flame,
heat or ignition sources.
DO NOT USE A MATCH, OPEN FLAME OR SMOKE DURING
LEAK TESTING.
WHAT YOU’LL NEED FOR TESTING:
1. A mixture of 50% liquid dish soap and 50% water.
2. A brush or cloth to apply the mixture.
CLEANING & MAINTENANCE
8
WARNING