2.0 SYSTEM OVERVIEW
UL S2203
Cheetah Xi Install ation Manual
2-5
FM
P/N: 06-356
Rev 9, 10/2016
Exhib it 2-3: MINIMUM SYSTEM CONFIGURATIONS – CONT.
This table indicates the minimum co mponents needed to meet the intended
applications.
Y = Yes
N = No
O = Optional
P
r
o
t
e
c
t
e
d
P
r
e
m
i
s
e
s
(
L
o
c
a
l
)
C
e
n
t
r
a
l
S
t
a
t
i
o
n
(
P
P
U
)
R
e
m
o
t
e
S
u
p
e
r
v
i
s
i
n
g
S
t
a
t
i
o
n
(
P
P
U
)
P
r
o
p
r
i
e
t
a
r
y
S
u
p
e
r
v
i
s
i
n
g
S
t
a
t
i
o
n
(
P
P
U
/
S
S
U
)
R
e
l
e
a
s
i
n
g
S
e
r
v
i
c
e
U
L
L
i
s
t
e
d
F
M
A
p
p
r
o
v
e
d
Part Number
Description
63-1052
Photoelectric Detector
O
O
O
O
O
Y
Y
63-1058
Photoelectric Detector, Isolator Version
O
O
O
O
O
Y
Y
67-033
Ionization Detector
O
O
O
O
O
Y
Y
67-034
Ionization Detector, Isolator Version
O
O
O
O
O
Y
Y
63-1053
Combination Photo/135°F Heat Detector
O
O
O
O
O
Y
Y
63-1059
Combination Photo/135°F Heat Detector, Isolator Version
O
O
O
O
O
Y
Y
60-1039
Heat Detector, 135°F-190°F (57-88°C) FT/RR
O
O
O
O
O
Y
Y
60-1040
Heat Detector, 135°F-190°F (57-88°C) FT/RR, Isolator
O
O
O
O
O
Y
Y
63-1054 (EBF)
Detector Base, 6-inch
O
O
O
O
O
Y
Y
63-1060 (EBFI)
Detector Base, 6-inch, Isolator Version
O
O
O
O
O
Y
Y
63-1055 (EB)
Detector Base, 4-inch
O
O
O
O
O
Y
Y
63-1061 (EBI)
Detector Base, 4-inch, Isolator Version
O
O
O
O
O
Y
Y
63-1064 (EBS)
Sounder Base, 6-inch
O
O
O
O
O
Y
Y
63-1063 (EBR)
Relay Base, 6-inch
O
O
O
O
O
Y
Y
55-045
(Note 1)
MMM – Mini Monitor Module
O
O
O
O
Y
Y
Y
55-050
(Note 1)
MMM – Mini Monitor Module, Isolator Version
O
O
O
O
Y
Y
Y
55-041
(Note 1)
MM – Monitor Module 4-inch
O
O
O
O
Y
Y
Y
55-046
(Note 1)
MM – Monitor Module 4-inch, Isolator Version
O
O
O
O
Y
Y
Y
20-1063
APS – Addressable Pull Station
O
O
O
O
O
Y
Y
20-1064
APS – Addressable Pull Station, Isolator Version
O
O
O
O
O
Y
Y
55-052
RCM - Release Control Module
O
O
O
O
O
Y
Y
55-053
RCM – Release Control Module, Isolator Version
O
O
O
O
O
Y
Y
55-042
SCM – Supervised Control Module
O
O
O
O
Y
Y
Y
55-047
SCM – Supervised Control Module, Isolator Version
O
O
O
O
Y
Y
Y
10-2360
Series Solenoid Diode/Resistor
O
O
O
O
Y
Y
Y
10-2413
Masterbox Interface
O
O
O
O
O
Y
Y
55-043
RM – Relay Module
O
O
O
O
O
Y
Y
55-048
RM – Relay Module, Isolator Version
O
O
O
O
O
Y
Y
63-1057
Photo Duct Detector
O
O
O
O
O
Y
Y
63-1062
Photo Duct Detector, Isolator Version
O
O
O
O
O
Y
Y
63-1158
Duct Detector Housing (isolator base)
O
O
O
O
O
Y
Y
68-140
FAAST XM Aspirating Smoke Detector
O
O
O
O
O
Y
Y
68-302
FAAST XT Aspirating Smoke Detector
O
O
O
O
O
Y
Y
68-509
FAAST XS Aspirating Smoke Detector
O
O
O
O
O
Y
Y
Notes:
1.
Module is required to monitor sprinkler system components (e.g. Waterflow, Tamper, Low Air, etc.).