background image

INSTALLATION INSTRUCTION

ARPOOL S

LIGHTING FIXTURES

All dimensions are given according to the SI system of units (mm, kg, °C), 
additional dimensions that are written in brackets, are given according to 
the U.S. measurement system (in, lbs, °F).

GENERAL REMARKS ON SAFETY

- Read all of these instructions before installing fixtures. 
- Keep all of the instructions for future reference. 
- Turn off power before installing fixture. 
- Installation is to be performed by a qualified electrician only. 
- All installations  are to conform to the standards of the National Electri-
cal Code as well as all local jurisdictional codes and regulations. 
- Any modification of the luminaire  will void any and all written or 
implied warranties. 
- Do not open the fixture - this will void the IP rating. 
- The manufacturer accepts no responsibility for damage to persons or 
property arising through improper use or installation. 

WARRANTY

All products are factory tested and are guaranteed free from factory 
defect for a period of 3 years under following terms: 
- Product has not been subject to incorrect voltage or polarity connec-
tion. 
- Product has not been subject to physical or atmospheric damage. 
- Product has been returned and factory evaluated for defect or mal-
function. 
- All drivers and controllers are approved for use by FILIX. 
- The luminaire factory seal ( IP rating ) has not been compromised

The manufacturer accepts no responsibility for damage to persons or 
property arising through improper use or installation.

Floor

Wall

Ceiling

Under 

water

POSSIBLE INSTALLATION POSITIONS

*Do not expose to a static load

12Vdc
CLASS II

IP68

IK10

For WET 
location

Calculate the maximum power consumption  and use appropriately sized 
drivers/controllers

This product must be installed in accordance with the applicable installa-
tion code by a person familiar with the construction and operation of the 
product and  the hazards involved.

Ø100 (3.9")

Ø58 (2.2")

WIRING MARKINGS

Fixture 1

Fixture 2

Fixture 3

Attention Info

Electrical Info

Humidity Info

Luminaries

Outer  housings

Confirmation 
Mark

Ingress 
protection

Temperature 
range

Underwater 
fixture

Pressure 
range

Impact resis-
tance range

Pictures/
drawings

Power supply 
type

Docs / certifi-
cations

Mechanical

Safety

Exclusion

Material Type

LEGEND

inter-lux

.com

CABLE WIRING MARKINGS

Black (+ Pole)

White (- Pole)

Black (+ Pole)

Red (- Red)

Green (- Green)
Orange (- Blue)

ARPOOL S

Note: for wet location use IP68 connector

INSTALLATION GUIDE

1

2

3

4

1. Pass the cable through conduit
2.Tighten cable gland 
3.Place fixture in installation housing and fix it with screws 
4.Fix fixture with supplied screws on to housing

TRIM

TRIMLESS

Stainless 
Steel 316L

THE LUMINAIRE  IS ONLY SUITABLE FOR OPERATION UNDER WATER 
(INSTALLATION POSITION  460mm(18”) < 3000mm(9’9’) UNDER 
WATER SURFACE) 

Except when the luminaire is installed in an area of the swimming pool 
that is not used for swimming and the lens is adequately guarded to 
keep any person from contacting it, the luminaire shall be installed in 
or on a wall of the pool, with the top of the lens opening not less than 
457mm (18 inches) below the normal water level of the pool.

White (- White)

Black (+ Pole)

Red (- Red)

Green (- Green)
Orange (- Blue)

White

RGB

RGBW

Reviews: