INSTALLATION INSTRUCTION
ARPOOL S
LIGHTING FIXTURES
All dimensions are given according to the SI system of units (mm, kg, °C),
additional dimensions that are written in brackets, are given according to
the U.S. measurement system (in, lbs, °F).
GENERAL REMARKS ON SAFETY
- Read all of these instructions before installing fixtures.
- Keep all of the instructions for future reference.
- Turn off power before installing fixture.
- Installation is to be performed by a qualified electrician only.
- All installations are to conform to the standards of the National Electri-
cal Code as well as all local jurisdictional codes and regulations.
- Any modification of the luminaire will void any and all written or
implied warranties.
- Do not open the fixture - this will void the IP rating.
- The manufacturer accepts no responsibility for damage to persons or
property arising through improper use or installation.
WARRANTY
All products are factory tested and are guaranteed free from factory
defect for a period of 3 years under following terms:
- Product has not been subject to incorrect voltage or polarity connec-
tion.
- Product has not been subject to physical or atmospheric damage.
- Product has been returned and factory evaluated for defect or mal-
function.
- All drivers and controllers are approved for use by FILIX.
- The luminaire factory seal ( IP rating ) has not been compromised
The manufacturer accepts no responsibility for damage to persons or
property arising through improper use or installation.
Floor
Wall
Ceiling
Under
water
POSSIBLE INSTALLATION POSITIONS
*Do not expose to a static load
12Vdc
CLASS II
IP68
IK10
For WET
location
Calculate the maximum power consumption and use appropriately sized
drivers/controllers
This product must be installed in accordance with the applicable installa-
tion code by a person familiar with the construction and operation of the
product and the hazards involved.
Ø100 (3.9")
Ø58 (2.2")
WIRING MARKINGS
Fixture 1
Fixture 2
Fixture 3
Attention Info
Electrical Info
Humidity Info
Luminaries
Outer housings
Confirmation
Mark
Ingress
protection
Temperature
range
Underwater
fixture
Pressure
range
Impact resis-
tance range
Pictures/
drawings
Power supply
type
Docs / certifi-
cations
Mechanical
Safety
Exclusion
Material Type
LEGEND
inter-lux
.com
CABLE WIRING MARKINGS
Black (+ Pole)
White (- Pole)
Black (+ Pole)
Red (- Red)
Green (- Green)
Orange (- Blue)
ARPOOL S
Note: for wet location use IP68 connector
INSTALLATION GUIDE
1
2
3
4
1. Pass the cable through conduit
2.Tighten cable gland
3.Place fixture in installation housing and fix it with screws
4.Fix fixture with supplied screws on to housing
TRIM
TRIMLESS
Stainless
Steel 316L
THE LUMINAIRE IS ONLY SUITABLE FOR OPERATION UNDER WATER
(INSTALLATION POSITION 460mm(18”) < 3000mm(9’9’) UNDER
WATER SURFACE)
Except when the luminaire is installed in an area of the swimming pool
that is not used for swimming and the lens is adequately guarded to
keep any person from contacting it, the luminaire shall be installed in
or on a wall of the pool, with the top of the lens opening not less than
457mm (18 inches) below the normal water level of the pool.
White (- White)
Black (+ Pole)
Red (- Red)
Green (- Green)
Orange (- Blue)
White
RGB
RGBW