FIXTURE DIMENSIONS

WIRING

WIRE MARKINGS

+

BLACK WIRE

-

WHITE WIRE

OPTION WITH SINGLE LED COLOR

+

BLACK WIRE

-R RED WIRE

-G GREEN WIRE

-B ORANGE WIRE

-W WHITE WIRE

OPTION WITH RGBW LED COLOR

www.filixlighting.com

2/3

NOTE:

IT ADVISED THAT CABLE LENGTH IS LONG ENOUGH THAT IT REACHES DRY AREA FOR SPLICE CONNECTION DRY AREA.

CONTROL GEAR USED TO POWER THIS LUMINAIRE SHALL BE SELV TYPE; HIGHEST ALLOWED UOUT TO BE MAX 10%

OF THE NOMINAL VOLTAGE OF CONTROL GEAR;MAXIMUM ALLOWED WIRING DISTANCE BETWEEN CONTROL GEAR AND

LUMINAIRE WITH STANDARD SUPPLIED CABLE IS 9 m OR 30˝. INSTALLATION OF LONGER WIRING LENGTHS SHOULD BE

DISCUSSED WITH MANUFACTURER PRIOR THE FIXTURE ORDERING. WHERE LUMINAIRE IS DELIVERED WITH CONNECTING

LEADS AND WITHOUT A MEANS OF CONNECTION TO THE POWER SUPPLY TERMINAL BLOCKS MAY BE USED (TERMINAL

BLOCKS  SUPPLIED  BY  MANUFACTURER).  IF  TERMINAL  BLOCKS  IS  LOST  IT  SHALL  BE  REPLACED  FOR  THE  SAME  IP

RATING AS THE LUMINAIRE ITSELF, WITH RATED VOLTAGE OF MIN. 400 V AND RATED CONNECTION CAPACITY OF 10A.

CONNECTION  WIRE  ENDS  COMING  FROM  POWER  SUPPLY  TO  BE  PREPARED  AS  TERMINAL  BLOCK  MANUFACTURER

RECOMMENDS. TERMINAL BLOCK SHOULD BE PLACED IN A LOCATION WHERE IT DOESN'T NOT AFFECT THE LUMINAIRE

OPERATION.