FIXTURE DIMENSIONS
WIRING
WIRE MARKINGS
+
BLACK WIRE
-
WHITE WIRE
OPTION WITH SINGLE LED COLOR
+
BLACK WIRE
-R RED WIRE
-G GREEN WIRE
-B ORANGE WIRE
-W WHITE WIRE
OPTION WITH RGBW LED COLOR
www.filixlighting.com
2/3
NOTE:
IT ADVISED THAT CABLE LENGTH IS LONG ENOUGH THAT IT REACHES DRY AREA FOR SPLICE CONNECTION DRY AREA.
CONTROL GEAR USED TO POWER THIS LUMINAIRE SHALL BE SELV TYPE; HIGHEST ALLOWED UOUT TO BE MAX 10%
OF THE NOMINAL VOLTAGE OF CONTROL GEAR;MAXIMUM ALLOWED WIRING DISTANCE BETWEEN CONTROL GEAR AND
LUMINAIRE WITH STANDARD SUPPLIED CABLE IS 9 m OR 30˝. INSTALLATION OF LONGER WIRING LENGTHS SHOULD BE
DISCUSSED WITH MANUFACTURER PRIOR THE FIXTURE ORDERING. WHERE LUMINAIRE IS DELIVERED WITH CONNECTING
LEADS AND WITHOUT A MEANS OF CONNECTION TO THE POWER SUPPLY TERMINAL BLOCKS MAY BE USED (TERMINAL
BLOCKS SUPPLIED BY MANUFACTURER). IF TERMINAL BLOCKS IS LOST IT SHALL BE REPLACED FOR THE SAME IP
RATING AS THE LUMINAIRE ITSELF, WITH RATED VOLTAGE OF MIN. 400 V AND RATED CONNECTION CAPACITY OF 10A.
CONNECTION WIRE ENDS COMING FROM POWER SUPPLY TO BE PREPARED AS TERMINAL BLOCK MANUFACTURER
RECOMMENDS. TERMINAL BLOCK SHOULD BE PLACED IN A LOCATION WHERE IT DOESN'T NOT AFFECT THE LUMINAIRE
OPERATION.