background image

Specification

Details

Warranty

1 year

Certifications

CE and FDA Accession No. 9320350-008 

1

Viscosities tested at ambient temperature: 25 °C ±2 degrees; 77 °F ±2 degrees

General information

In no event will the manufacturer be liable for direct, indirect, special, incidental or consequential
damages resulting from any defect or omission in this manual. The manufacturer reserves the right to
make changes in this manual and the products it describes at any time, without notice or obligation.
Revised editions are found on the manufacturer’s website.

Safety information

N O T I C E

 

The manufacturer is not responsible for any damages due to misapplication or misuse of this product including,
without limitation, direct, incidental and consequential damages, and disclaims such damages to the full extent
permitted under applicable law. The user is solely responsible to identify critical application risks and install
appropriate mechanisms to protect processes during a possible equipment malfunction.

Please read this entire manual before unpacking, setting up or operating this equipment. Pay
attention to all danger and caution statements. Failure to do so could result in serious injury to the
operator or damage to the equipment.
Make sure that the protection provided by this equipment is not impaired. Do not use or install this
equipment in any manner other than that specified in this manual.

Use of hazard information

D A N G E R

 

Indicates a potentially or imminently hazardous situation which, if not avoided, will result in death or serious injury.

W A R N I N G

 

Indicates a potentially or imminently hazardous situation which, if not avoided, could result in death or serious
injury.

C A U T I O N

 

Indicates a potentially hazardous situation that may result in minor or moderate injury.

N O T I C E

 

Indicates a situation which, if not avoided, may cause damage to the instrument. Information that requires special
emphasis.

Precautionary labels

This is the safety alert symbol. Obey all safety messages that follow this symbol to avoid potential
injury. If on the instrument, refer to the instruction manual for operation or safety information.

This symbol indicates that a risk of electrical shock and/or electrocution exists.

4

   

English

Summary of Contents for PC9001

Page 1: ......

Page 2: ...ticle size channel 4 6 14 and 21 m ISO MTD Storage operating humidity 97 relative humidity non condensing Fluid compatibility Hydraulic and lubrication oils mineral synthetic phosphate ester compatibl...

Page 3: ...ire manual before unpacking setting up or operating this equipment Pay attention to all danger and caution statements Failure to do so could result in serious injury to the operator or damage to the e...

Page 4: ...is equipment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of the FCC rules These limits are designed to provide reasonable protection against ha...

Page 5: ......

Page 6: ......

Page 7: ......

Page 8: ...6 Pink RS232 TXD transmit data 7 Blue 8 Red 9 Orange RS232 GND signal return 10 Tan RS485 A signal A of differential serial driver pair 11 Black RS485 B signal B of differential serial driver pair 12...

Page 9: ...shield ground connection 13 14 15 Table 3 Male connector wires DB15 to DB9 cable Pin number Color Function 1 Red1 Power input 9 to 33 VDC 2 Black1 Power ground return 3 White1 Alarm driver 4 5 Red2 R...

Page 10: ......

Page 11: ...TATUS indicator light Shows a numerical system status code Flashes when there is a system alarm T C indicator light Shows the system temperature from the last completed sample XX X SAE indicator light...

Page 12: ...P C 9 0 0 1...

Page 13: ...ll Codes or Highest Code Display NAS Codes All Codes or Highest Code Display SAE Codes All Codes or Highest Code 4 To calculate average counts select Calculate Average Counts and adjust the number of...

Page 14: ...P C 9 0 0 1...

Page 15: ...P C 9 0 0 1...

Page 16: ......

Page 17: ...eterioration at least every 6 months more frequently if conditions are harsh If the hoses need to be replaced do these steps 1 Remove the pressure from the system 2 Remove the power from the instrumen...

Page 18: ......

Page 19: ...ed on ISO 4406 To change Filtertechnik codes to ISO codes delete all of the digits to the right of the decimal point Do not change the value either up or down For example a Filtertechnik code readout...

Page 20: ...5 13 1 44 16 1 352 19 1 2750 7 2 0 772 10 2 6 13 2 48 16 2 384 19 2 3000 7 3 0 838 10 3 6 5 13 3 52 16 3 416 19 3 3250 7 4 0 904 10 4 7 13 4 56 16 4 448 19 4 3500 7 5 0 97 10 5 7 5 13 5 60 16 5 480 1...

Page 21: ...0 21 8 18000 23 8 72000 25 8 288000 27 8 1168000 21 9 19000 23 9 76000 25 9 304000 27 9 1234000 NAS codes Table 10 shows the original NAS 1638 contamination limits by maximum particle counts per 100 m...

Page 22: ...26 4 Class 5 25 000 9730 1730 306 53 8 Class 6 50 000 19 500 3460 612 106 16 Class 7 100 000 38 900 6920 1220 212 32 Class 8 200 000 77 900 13 900 2450 424 64 Class 9 400 000 156 000 27 700 4900 848 1...

Reviews: