background image

21 | 

P a g e

 

 

Reverse Osmosis Membrane Replacement 

 
 RO versions (RO) 

(every 3 years)

  

 

a)

 

Use the same procedure as above sec a-c.  

b)

 

Remove  the  RO  stage  from  the  clips.  Disconnect  the  white 

tubing from the RO housing cap.  

 

c)

 

Remove the cap from the housing by unscrewing it.  

d)

 

Using  a  pair  of  pliers,  remove  the  RO  element  from  the 

housing by grasping the tube end and pulling it out.  

 

e)

 

Use  RO  filter  replacement  P/N  CSM50  (50gpd).  Insert  the 

element  into  the  housing  with  double  “o”-ring  end  going  in 

first–toward  the  bottom  of  the  housing.  Make  sure  the  “o”-

rings are sealed. Replace the cap. Reconnect the white tubing. 

Proceed as in above sec. g.  

 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 

Figure. 8 

RO Membrane Installation 

 
 
 
 
 
 
 
 
 

Summary of Contents for FW-2000

Page 1: ...1 P a g e MODEL FW 2000 OPERATION MANUAL ...

Page 2: ...Flush pg 16 Cleaning and Maintenance pg 17 Sanitization p g 18 Filter Replacement pg 19 Reverse Osmosis Membrane Replacement pg 20 Troubleshooting pg 21 Specifications pg 22 Warranty pg 22 List of Figures Figure 1 Assembly Drawing Model H2O 2000 pg 5 Figure 2 Faucet Operation pg 6 Figure 3 Hot Cold Power On Off Switch pg 6 Figure 4 Water Cooler Connections pg 11 Figure 5 Drain Connections for RO M...

Page 3: ...facture a wide range of models to fit any home or office application The H2O 2000 Model has 3 temperature faucets cold water is chilled around 44ºF hot water is heated at 180ºF and ambient All International H2O models are manufactured and marked as RO or F assemblies The RO assembly utilizes CSM Reverse Osmosis water purification technology which produces pure safe water from city or well water Th...

Page 4: ... front Open the bottom panel to assure that the filter system is intact Look at the back of the cooler to see if the compressor is secure and has not broken from the mounting Inspect filter system to see that nothing is damaged or dislodged from shipping Description Model H2O 2000 The H2O 2000 Model provides water at 3 different temperatures dispensed from three spigots hot cold and ambient The as...

Page 5: ...5 P a g e constant level of filtered water Both models are available with reverse osmosis RO or standard filter F versions Description Model H2O 2000 ...

Page 6: ...let and press the cold hot faucets until a steady stream of water comes out Figure 2 Faucet operation Make sure the tanks are filled with water before continuing to the next step Turn on the hot cold switches located on the back of the cooler Both hot cold elements will begin chilling and heating the water inside the unit Indicator lights will also illuminate of the front of the cooler ...

Page 7: ...7 P a g e Figure 2 Hot and cold power on off switch Operation Cont ...

Page 8: ...8 P a g e Drain Container Operation ...

Page 9: ...9 P a g e Cup Dispenser Operation ...

Page 10: ...10 P a g e Positioning the Cooler 1 It is not recommended to install this cooler in an area were water may cause severe or costly damage ...

Page 11: ...r where it can be hit or bumped by Vacuum cleaners or floor waxing machines This can cause breaks in the waterline connection fittings and compressor tubing Water Cooler Connections When you receive the water cooler the water connections on ...

Page 12: ...1 4 plastic tubing should be used for making the Feed Water and Drain connections If hard copper tubing is used for the Feed Water and Drain connections the bulkhead fittings must be changed to a metal fitting Figure 4 Water Cooler Connections Feed Water Connections To connect the feed water use the supplied self piercing saddle valve to connect to the cold water supply line under the sink ...

Page 13: ...he valve Clamp the saddle valve over copper or plastic feed line cold water only Turn the handle on the valve until the needle stem pierces the tube Then retract the needle 1 2 turns to start water flow See Photo inset Drain Connection Applies to models with Reverse Osmosis RO only ...

Page 14: ...ening in the drain outlet saddle as a guide drill a 1 4 hole in the drain pipe Clean any debris out of the drain saddle connection Connect the drain line to the cooler using the 1 4 black tubing supplied Figure 5 Drain Connections for RO models EZ Connections The standard tubing connections on the water coolers are EZ connect fittings Use the tubing and follow the instructions below in fig 7 to ma...

Page 15: ...hich hold the tube firmly in position while the O ring pro vides a permanent leak proof seal Pull to check secure Pull on the tube to check it is secure It is good practice to test the system prior to leaving site and or before use Push in collet and remove tube Disconnect To disconnect ensure the system is depressurized before removing fitting Push in collet squarely against face of fitting With ...

Page 16: ...to push out air and carbon fines When water runs clear turn off ball valve and re connect the tube to the filter Turn on the water to the filter system by opening the ball valve inside the cooler 1 4 turn handle in line with tube is on Check all connections to assure there are no leaks Figure 6 Filter configuration model F with cooler door opened Tank Flush Flush tanks out by draining all water th...

Page 17: ... Remove the top cover of the cooler by removing 2 screws from back of top cover Pull the cover off exposing the main tank This model uses a mechanical float valve to control flow to the tank The unit does not have to be plugged in to start water flow Water will flow into the ambient cold and then the hot tank as well Let cooler tanks fill with the filtered water until full about 1 hours for the RO...

Page 18: ...18 P a g e Sanitize ...

Page 19: ... 5 10 minutes Drain the water then let water from filters refill tank and drain a second time Remember to drain from dispensing spigots also Note Upon completion of cleaning wait at least 10 minutes after the power cord is plugged in before turning on the Hot and Cold Water buttons Filter Replacement ...

Page 20: ...se the ball valve to stop water flow through the filters d Place a towel under the filters to catch water The filters will have water in them which will run out when the filters are unlocked e Twist the filters to remove them from their housings f These filters are disposable encapsulated filters Remove and discard the entire filter body Replacement filters are sold as a set 1st Stage sediment fil...

Page 21: ...rom the housing by unscrewing it d Using a pair of pliers remove the RO element from the housing by grasping the tube end and pulling it out e Use RO filter replacement P N CSM50 50gpd Insert the element into the housing with double o ring end going in first toward the bottom of the housing Make sure the o rings are sealed Replace the cap Reconnect the white tubing Proceed as in above sec g Figure...

Page 22: ... dispenser Clean wire condenser every three months Place cooler in a well ventilated area Adjust thermostat Hot Water doesn t flow out of spigot Air may be trapped in the line Hold the spigot down for 30 seconds to relieve air Won t cool Controls not set Turn cold temperature switch on at back Panel not lit No power Check that the power cord is in the socket and turn on the cold hot buttons on the...

Page 23: ...O 2000 Voltage Frequency AC110V Dimensions L 14 x W 13 x H 48 Weight empty 70 lb Hot Tank Capacity 5 gal Ambient Tank Capacity 2 3 gal Cold Tank Capacity 1 gal Power Consumption Hot Water 500W Cold Water 100W Electric Power Cord Length 6Ft ...

Page 24: ...any for damage due to water leakage or other secondary effects from any component defect Labor is not covered in this warranty The warranty applies when Conditions of Operation below are met Conditions of Warranty Water System Pressure 35 100psi Temperature 40 100degrees F Water PH range 4 10 Max TDS 1500 PPM Turbidity 1 0 NTU Water Hardness 20gpg Iron 0 1 mg l Manganese 0 1 mg l Hydrogen Sulfide ...

Page 25: ...25 P a g e Mailing Address FilterWater com P O Box 968 Southampton PA 18966 USA http www FilterWater com Tel 800 439 0263 Fax 215 354 0304 Email Sales filterwater com ...

Reviews: