17
BLOWER MODULE REPLACEMENTS
! To avoid any risk of electrical discharge, turn off and unplug the Filtrabox
before doing any activities that require disassembly of the unit.
EXPAND 3
comes standard with
3
Blower Modules
.
Blower Modules
can be easily replaced by removing
a few screws and disconnecting/connecting two cables.
Replacement of Blower Modules:
1.
Loosen all
4 Strap Clamps
on the
Lid
by pressing the lever on the clamps. Unhook the
Strap
Clamps
and remove the
Lid
by lifting it straight up off the assembly.
2.
At the rear of the
Lid
are two stabilizing fins. Stand the lid on its fins, on the floor or a
table.
3.
Using the folding handles, lift the
Carbon Filters
off of the
HEPA filter
and set the
Carbon Filter
aside.
4.
Lift the
HEPA filter
off of the
Main Chassis
and set it aside.
5.
On the back of the Electronics Module, there is a
Blower Connector Access Panel.
See
the “Machine Diagram”.
Remove the two screws on the panel. Pull the panel off to
expose the
Blower Connector
. Unclip the connector.
6.
Locate the 4 screws at the base of the
Blower A and/or B Module(s).
Remove the
screws.
7.
Slide the spent
Blower Module(s)
sideways out from the machine.
8.
Slide new
Blower Module(s)
back in and re-install the 4 screws.
9.
Reconnect the
Blower Connector
(s) and close the
Blower Connector Access
Panel
with
the two screws.
10.
Reassemble the Filtrabox as per the
ASSEMBLY
instructions.
11.
Go to the
User Interface
and press the
“Menu/Enter”
button. Press the
“Left or Right”
arrow keys until you reach
“Set # of Blwrs”
on the screen. Press the
“Menu/Enter”
button. Press the “Up or Down”
arrow keys to select 5 blowers. The
Calibration
sequence will self-initiate.
Calibration
cannot be interrupted.