background image

PG

 10

PG

 10

HVAC Setup on Screen 

 

 IMPORTANT:

 Make sure the 3M-50 is powered up and the 

mode is set to OFF. HVAC selection switches must be set first 

[pg 8].

• With mode in OFF press MENU and touch HVAC SET UP.

• Use +/- icons to select HVAC SET UP number on screen.

The LCD display will show your selection and indicate the 

number of stages you have selected. During setup, 2nd stage 

will blink when both heat and cool have 2nd stages. 

If you have a Normal HVAC system and  

you want fast temperature recovery...
HEAT  and  COOL                   select  

1

2 stage HEAT, 1 stage COOL select  

2

   

2 stage HEAT, 2 stage COOL select  

3

   

If you want efficient [but slower] recovery...

2 stage HEAT, 1 stage COOL select  

4

   

2 stage HEAT, 2 stage COOL select  

5

 

  

NOTE: For 2 stage systems your 3M-50 can recover from a temperature setback in 2 ways: 1] Fast Recovery - This uses your 2nd 

stage to bring the house to Target Temperature. This may use slightly more energy. 2] Efficient Recovery -This uses the 2nd stage to 

bring your house to within a few degrees of the Target Temperature and then uses the 1st stage to go the last bit. (See setting the dif-

ferential in the operating guide). This is more efficient.

HEAT

2

ND

STG

HVAC

SETUP 

COOL

If you have a HEAT PUMP HVAC 

system...
HEAT PUMP with AUX heat     select  

A

    (fast recovery)

HEAT PUMP with AUX heat     select  

b

   (efficient recovery)

   

HEAT PUMP no AUX heat        select  

C

 

Summary of Contents for 3M-50

Page 1: ...t is designed for use with 3 AA alkaline batteries and or 24 VAC C wire or a 12 24 AC or DC source and millivolt gas systems Each thermostat relay load should be limited to 1 0 amp higher amperage may cause damage to the thermostat Caution To avoid electrical shock and to prevent damage to the furnace air conditioner and thermostat disconnect the power supply before beginning work This can be done...

Page 2: ...there are unusual heating conditions such as in direct sunlight near a lamp radio television radiator register fireplace near hot water pipes in a wall or near a stove on the other side of a wall Do not locate in unusual cooling conditions such as on a wall separating an unheated room or in a draft from a stairwell door or window Do not locate in a damp area This can lead to corrosion that will sh...

Page 3: ... carefully before removing any wiring from existing thermostat Wires must be labeled before they are removed THERE IS NO STANDARD COLOR CODE When remov ing wires from their terminals ignore the color of the wires and LABEL THEM by the lettered terminal where they were screwed Label the wires one at a time You must label all the wires before you proceed With all wires labeled remove them from the o...

Page 4: ...a standard 12 24V AC or DC wall transformer A constant power source is required when using a radio module IMPORTANT If you have both RH and RC you need to remove the jumper wire between these 2 terminals Prepare Wires Please follow these guidelines for safe and secure wire connections You will need at least 2 6 of wire for each of your connections to the 3M 50 If you do not have enough wire splice...

Page 5: ...rom Furnace RC C Y RH W C W Y RH G 4 Wire Heat Cool From Furnace G C Y RH W C W RH G 3 Wire Heat From Furnace C RH G W From Furnace C W C W RH RH 2 Wire Heat From Furnace W RH A W RH A 3 Wire Zoned Hot Water WIRES WIRES WIRES WIRES WIRES G RH C W2 W Y Y2 RH G 2 stage Cool 2 stage Heat From Furnace Y2 C W Y W2 C B or O W2 Y RH G 5 Wire Heat Pump w Aux Heat From Furnace RH C O or W2 B G Y G C B or O...

Page 6: ...rminal area Do not bunch wires behind the 3M 50 Feed any slack back into the wall opening Connect Your Wires Connect labeled wires only to a terminal with the same letter label Insert the wire in the terminal well and tighten the screw securely NOTE If you wish you can mount the 3M 50 to the wall first and then connect the wires The 3M 50 can be externally powered with a power source rated from 12...

Page 7: ...he 3M 50 to the wall with the screws provided 4 If you are mounting the 3M 50 to sheet rock or if you are using the old mounting holes use the plastic anchors provided 5 Mark first and drill a 3 16 in 4 8mm hole for the insert at each screw location then mount the unit Screw to wall Place wires like this C B O WW2 YY2RHRCG A from HEAT COOL system C B O WW2 YY2RHRCG A C W Y RH G Wall Wires Wall anc...

Page 8: ...l 3 AA Batteries Install 3 AA alkaline batteries required following the marked polarity in the battery compartment Put the lower battery in negative end first against the spring then push the positive end in Then insert the last 2 batteries as shown IMPORTANT Press the RESET button under top cover to implement the HVAC switch selections With all the wires connected it is time to turn the AC power ...

Page 9: ...or a month or more you should replace the batteries as a precaution against battery failure in your absence Always use new alkaline batteries Failing to replace the batteries when necessary could cause the thermostat to lose power or malfunction If the thermostat loses power then the thermostat will not control the temperature which could result in your HVAC system not functioning as you intended ...

Page 10: ...tage COOL select 3 If you want efficient but slower recovery 2 stage HEAT 1 stage COOL select 4 2 stage HEAT 2 stage COOL select 5 NOTE For 2 stage systems your 3M 50 can recover from a temperature setback in 2 ways 1 Fast Recovery This uses your 2nd stage to bring the house to Target Temperature This may use slightly more energy 2 Efficient Recovery This uses the 2nd stage to bring your house to ...

Page 11: ...n Touch the icon and raise the Target Temperature to 90 o F allow the system 2 minutes to respond Verify that heat is blowing from the system Return the Target Temperature to a nomal setting Return mode to OFF by pressing the mode button If you have a heat pump leave in off for 4 minutes before checking COOL TO CHECK COOL do not operate AC if the outside temp is below 65 o F Set the mode to COOL b...

Page 12: ...used with line voltage systems This thermostat is digital and your desired heat or cool temperatures can easily be set on the large touch screen with the buttons A minimum 4 minute off time protects the compressor from damage This thermostat runs on 3 AA batteries The 3M 50 can be externally powered with a power source rated from 12V to 24V AC or DC at 300ma or greater If used connect to the C and...

Page 13: ...r RH wire to the RH terminal This connects the heat power STEP 2 Connect the W wire to the W terminal This connects the heat STEP 3 Connect the G wire to the G terminal on the thermostat This connects the fan STEP 4 Set HVAC selection switches to NORMAL and If you have gas or oil heat set the HEAT TYPE to GAS If you have electric heat set the HEAT TYPE to ELEC Your system is now connected to the 3...

Page 14: ... RH RC G WIRES 5 Wire Heat Cool STEP 1 Connect the W wire to the W terminal This connects the heat STEP 2 Connect the Y wire to the Y terminal This connects to the cooling compressor STEP 3 Disconnect the jumper between RH and RC terminals STEP 4 Connect the RH wire to the RH and the RC wire to the RC terminals This connects power STEP 5 Connect the G wire to the G terminal This connects the fan S...

Page 15: ...inal or B wire to the B This connects the change over valve If you have both O and B connect only the O wire to the O terminal and DO NOT connect B to B terminal see wire reference under Trane for B wire terminal STEP 2 Connect the W2 wire to W2 terminal This connects the auxiliary heat STEP 3 Connect the Y wire to Y terminal This connects the compressor STEP 4 Connect the R wire to RH terminal Th...

Page 16: ...minal This connects the fan STEP 7 Set HVAC selection switches to NORMAL and If you have gas or oil heat set the HEAT TYPE to GAS If you have electric heat set the HEAT TYPE to ELEC Your HVAC system is now connected to the 3M 50 Please Go To Page 6 W RH A WIRES 3 Wire Zoned Hot Water For Solenoid valve or Motor valve connect the wires based on diagrams below to the correct terminal on the 3M 50 US...

Page 17: ...ge COOL control or 2nd stage compression for a heat pump G or F G FAN control C or X C 24VAC power to power thermostat NOTE TRANE uses B for this connection H H External Humidifier DH DH External De Humidifier EX EX external fresh air baffle B B Heat pump changeover cool to heat powered in heat O O Heat pump changeover heat to cool powered in cool B and O IMPORTANT If there are both B and O wires ...

Page 18: ...wer thermostat W or W1 W2 2nd stage HEAT X2 Emergency heat do not connect tape off Zoned Hot Water 2 wire Your Wires Thermostat Terminal R RH W W 3 Wire Motor Driven Valves R or 5 RH power W or 4 W heat ON Y or G or 6 the 3rd wire A heat OFF 3 Wire Solenoid Valves R RH power W A heat ON Y or G the 3rd wire W heat OFF Customer support Filtrete radiothermostat com 888 607 5824 or www radiothermostat...

Reviews: