EXTRAORDINARY MAINTENANCE
4.
Using the handle (2), in the vacuum head assembly, remove the vacuum head assembly from the
collection tank (rotating it and shifting it as indicated in the figure).
5.
Push down the locking lever (3) of the mesh (4) of the exhaust air filter.
To remove the vacuum motor sponge filter, proceed as follows:
6.
Remove the mesh (4) and the exhaust air filter (5).
7.
Replace the worn filter with the new one.
8.
Repeat the operations in reverse to reassemble.
To remove the vacuum motor cartridge filter, proceed as follows:
9.
Remove the mesh (4) and the exhaust air filter (5).
10.
Replace the worn filter with the new one.
12.
Repeat the operations in reverse to reassemble.
WARNING: It is advisable to pay attention to the direction of filtration, the mesh in the
filter should be positioned opposite the vacuum motor.
4.
REPLACING THE POWER CABLE
To replace the power cable, proceed as follows:
1.
Take the appliance to its designated maintenance area.
2.
Do what is required to make sure the machine is in a safe condition (see
MACHINE SAFETY
’”).
3.
Turn the power cable locking bracket locking lever (1).
WARNING: you are advised to always wear protective gloves, to avoid the risk of
serious injury to your hands.
Page 23