RESET DELAY MENU (VACUUM VAC. MOT)
Proceed as follows to change the “RESET DELAY” parameter in the brush motor menu:
1.
Display the "MACHINE BRUSHES SETTINGS" menu - see
2.
Display the “SERVICE” menu - see
3.
Display the “PARAMETERS” menu - see
“PARAMETERS MENU (SERVICE)” on page 17
4.
Display the “VACUUM SETS” menu - see
“VACUUM SETS MENU (PARAMETERS)” on page 46
.
5.
Display the “VAC. MOT” menu, see
“VAC. MOTOR MENU (VACUUM SETS)” on page 46
6.
Using buttons (1) and (2) (
Fig.1
) select the "RESET DELAY" screen (
Fig.2
).
7.
As soon as the “RESET DELAY” screen (
Fig.2
) is displayed, select the delay in seconds before the actuator
brings the squeegee to the "raised from the floor" position using buttons (3) and (4) (
Fig.1
).
N.B.:
the selected value will be visible in the text string (5) in the lower part of the screen (
Fig.2
).
8.
Confirm the selection by pressing the button (6) (
Fig.1
).
Vacuum
Vac. motor
300
[s]
Reset delay:
min:1
max:300
2
5
2
4
1
3
6
1
N.B.:
the “RESET DELAY” parameter is a time interval during which the squeegee remains in the working
position before lifting off the ground.
N.B.:
The “RESET DELAY” parameter is expressed in seconds (s), the numerical value is between a
minimum of 001 and a maximum of 300, the selectable increment is one unit.
N.B.:
The “RESET DELAY” parameter is set in the factory to 300.
N.B.:
if set to 300, the squeegee remains in the working position. This option remains active until the next
working mode change where the vacuum is not used (TRANSFER or PRE-WASHING).
VACUUM NOISE LEVEL MENU (VACUUM VAC. MOT)
Proceed as follows to change the “VACUUM NOISE LEVEL” parameter in the water motor menu:
1.
Display the "MACHINE BRUSHES SETTINGS" menu - see
2.
Display the “SERVICE” menu - see
3.
Display the “PARAMETERS” menu - see
“PARAMETERS MENU (SERVICE)” on page 17
4.
Display the “VACUUM SETS” menu - see
“VACUUM SETS MENU (PARAMETERS)” on page 46
.
5.
Display the “VAC. MOT” menu, see
“VAC. MOTOR MENU (VACUUM SETS)” on page 46
6.
Using buttons (1) and (2) (
Fig.1
) select the "VACUUM NOISE LEVEL" screen (
Fig.2
).
7.
As soon as the “VACUUM NOISE LEVEL” screen (
Fig.2
) is displayed, select the percentage of the absorption
voltage of the suction motors present in the vacuum system of the machine using buttons (3) and (4) (
Fig.1
).
Page 47