36
DAILY MAINTENANCE
2.
Disconnect the electrical connector (02) from the battery connector.
3.
Engage the parking brake by means of the lever (03) on the right side of the machine (only for BT versions).
4.
Remove the vacuum cover (04) and position on the support (05) designed for this purpose, positioned
at the rear of the machine.
WARNING: To use the support (05), simply turn the tongue outwards, and once the
support function is complete, the tongue can be turned back inwards.
5.
Turn the cup (06) anticlockwise and remove from the machine.
6.
Remove the recovery tank filter (07).
7.
Rinse the cup and filter carefully under running water.
8.
Reassemble all the elements.
WARNING: This operation must be carried out using gloves to protect against
contact with dangerous solutions.
41.
CLEANING THE BRUSH (B-BT VERSIONS)
To ensure effective floor cleaning, proper cleaning of the brush is necessary. In order to do this, proceed
as follows:
1.
Make sure the recovery tank is empty, otherwise empty it completely.
2.
Check that the squeegee body is raised above the ground; if not, lift using the lever (01) on the rear of
the machine.
3.
Engage the parking brake by means of the lever (02) on the right side of the machine (only for BT
versions).
4.
Put the machine in rest mode. Using the control handlebar (pushing downwards), lift the front part of
the machine so that the rear wheel rests on the floor.
5.
Press the brush release button (03) on the instrument control panel. As soon as the button is pressed,
you will see the question “RELEASE?” on the screen. Press the brush release button (03) on the
steering wheel again, to confirm.
WARNING: If the brush does not release, repeat the operation again until the brush
is released from the brush head.
WARNING: During this operation, check there are no people or objects near the
brush.
6.
Rinse the brush carefully under running water.
7.
Read the paragraph “ASSEMBLING THE BRUSH” before reassembling all components.
WARNING: This operation must be carried out using gloves to protect against
contact with dangerous solutions.