ADJUSTMENT
AND
INSPECTION
MAGNA 65-70-75-83
Doc. 10004978
Issued 27/03/2008
Rev. 00
P a g .
1 4 d i 19
Water unit inspection
1.
Check the cleanliness and the operation of the
solution filter
2.
Fill the solution tank and check there is no leakage on the
water circuit
3.
Verify there is no leakage on the
solenoid valve
and
especially on its hoses connections and on the
water cock
4.
Check if the detergent solution falls down regularly and
uniformly along the cleaning width
5.
Fill the recovery tank and check the sealing
6.
Check that the hose and the exhaust plug do not have any
leakages
7.
On the solution
pump
inlet the flow passes through an
adjustable
narrow neck
to get the right uniform water
spreading on the floor; to increase the water flow please
increase the diameter of this throttled pump inlet
.
Suction unit inspection
1.
Check the cleanliness and the functionality of the
filter
and
of the
float system
.
2.
Check the air sealing between the
tap
and the recovery tank
.
3.
Check the sealing on both suction hoses and squeegee hose
connection terminals.
4.
Check the cleanliness and the functionality of the black box
and the
pipe
.