background image

CONNECTION TO THE ELECTRICITY GRID

DANGER:

• 

To reduce the risk of fire, electric shocks or injury, please read and comply with all the safety 

instructions and warnings. This machine has been designed to be safe when it is used for 

cleaning in the manner specified. If damage to electrical or mechanical components is found, 

the machine must be repaired at the relative authorised service centre before use, in order to 

prevent further damage to the machine or physical injury to the user.

•  Before connecting the machine to the electric socket, make sure the electrical information on 

the serial number plate corresponds to that of the mains supply. 

The machine must only be 

powered with alternating current and with a voltage equal to that shown on the serial 

number plate

.

•  The power supply cable outlet must have an earth connection in compliance with the 

regulatory standards.

•  If the machine packaging contains the cable to connect to the mains supply, it should only be 

used for the above-mentioned machine.

•  Before using, check for any damage on the connection cable and on the power plug. If the 

cable is damaged, immediately contact a technician for restoring normal functioning.

•  Connect the machine only to an electrical connection installed by an electrical installer in 

conformity with IEC 60364-1.

•  Never touch the power plug with wet hands.

•  Make sure that the cable to the mains or the extension cable have not been damaged by 

having been walked on, crushed, pulled or the like. Protect the cable from heat and from 

contact with oils or sharp edges.

•  Regularly check that the cable connecting to the mains is not damaged, for example with 

signs of ageing or cracks. If the cable is damaged it should be replaced before using the 

machine again.

•  Protection against splashes of water and the mechanical strength need to be ensured also 

after any replacement of the joints of the power cable or the extension cable.

ATTENTION:

•  The procedure causes a short-term reduction in voltage.

•  In unfavourable grid conditions the other appliances could be damaged.

• 

This damage could occur if the grid impedance is less than 0.15Ω.

EXTENSION CABLES

CAUTION:

Only use the materials expressly recommended by 

a service technician as cable extensions (contact an 

authorised retailer) or else high quality models. When 

using an extension, respect its minimum cross-section.

CABLE LENGTH

CABLE SECTION

<16A

<25A

Up to 20m

1.5mm

2

2.5mm

2

From 20m to 50m 

2.5mm

2

4.0mm

2

5

Summary of Contents for Maxima Base E

Page 1: ...ORIGINAL INSTRUCTIONS DOC 10077476 Ver AA 01 2018 PROFESSIONAL SCRUBBING MACHINES USE AND MAINTENANCE MANUAL MAXIMA 2017 BASE E...

Page 2: ......

Page 3: ...r 13 Solution tank drainage cap 14 Squeegee body 15 Squeegee body support 16 Vacuum tube 17 Water flow adjustment tap 18 Brush support 19 Brush head body 20 Solution tank 21 Solution tank filler cap m...

Page 4: ...RECOVERY TANK 18 EMPTYING THE SOLUTION TANK 18 CLEANING THE WATER SYSTEM FILTER 18 CLEANING THE VACUUM TUBE 18 EXTRAORDINARY MAINTENANCE WORK 18 REPLACING THE BRUSH HEAD BRUSH 50BT VERSIONS 18 REPLAC...

Page 5: ...ately contact a technician for restoring normal functioning Connect the machine only to an electrical connection installed by an electrical installer in conformity with IEC 60364 1 Never touch the pow...

Page 6: ...physical sensorial or mental impairments and by persons with little experience and or little knowledge of the machine itself The machine must only be used by authorised trained personnel Do not use th...

Page 7: ...ing from heights Do not place any liquid containers on the machine The machine must only be used under temperature conditions ranging from 0 C to 40 C When using detergents to clean the flooring alway...

Page 8: ...onents remove rings watches and or clothing with metallic parts that might come into contact with the electrically powered components Do not work underneath the raised machine without adequate fixed s...

Page 9: ...d regulations in force Once the machine has reached the end of its service life the materials contained within it must be disposed of in an appropriate manner keeping in mind that the machine itself h...

Page 10: ...oned behind the squeegee body lifting chain STORING THE USE AND MAINTENANCE MANUAL The Use and Maintenance Manual must be stored in its special pouch close to the machine protected from liquids and an...

Page 11: ...sh rotations rpm 140 Brush head motor voltage nominal power V W 230 375 230 375 110 375 110 375 Maximum weight exerted on the brush head kg 21 27 21 27 Maximum possible gradient 2 Maximum ambient temp...

Page 12: ...the rear part of the machine to indicate the squeegee control lever rotation direction for bringing the squeegee to its idle position Battery connection symbol Located on the front of the solution ta...

Page 13: ...ry press the button 2 Fig 2 NB if the LED in the button switch 2 is on it means that the switch is set to I Fig 2 if the LED in the button switch 2 is off it means that the switch is set to 0 4 Raise...

Page 14: ...ng 5 adheres to the walls of the slit 5 Repeat the same operation for the right hand pin 2 3 1 1 2 4 3 5 6 Insert the vacuum tube 6 in the sleeve 7 in the squeegee body Fig 4 NB the tube must be posit...

Page 15: ...he main key switch to I turn the key 5 by a quarter turn to the left Fig 3 2 4 3 1 5 2 3 1 NB the steps for a complete scrubbing and drying cycle are explained below 6 Lower the brush head body and de...

Page 16: ...er 7 is pressed the machine will begin to move The lever is located underneath the control handlebars Fig 5 NB the vacuum motor will only begin to work when the squeegee body is in contact with the fl...

Page 17: ...o always wear protective gloves to avoid the risk of serious injury to hands 3 Release the recovery tank drainage tube on the back of the machine from the retainers Fig 1 4 Bend the end of the drainag...

Page 18: ...filter proceed as follows 1 Take the machine to the maintenance area 2 Make sure the machine has been secured see the section titled SECURING THE MACHINE CAUTION users are advised to always wear prot...

Page 19: ...ueegee body see ADJUSTING THE SQUEEGEE BODY RUBBER BLADES NB you are advised to replace both squeegee body blades in order to ensure good results when drying the floor 7 6 ADJUSTMENT INTERVENTIONS ADJ...

Page 20: ...re therefore used on smooth floors or floors with small joints On uneven floors or those with deep joints it is advisable to use softer bristles which can enter the gaps more easily Remember that when...

Page 21: ...ACHINE DOES NOT START There is a drive pedal fault Contact your nearest service centre NOT ENOUGH DETERGENT SOLUTION ON THE BRUSH The quantity of detergent solution in the water system is not sufficie...

Page 22: ...22 NOTE...

Page 23: ......

Page 24: ...FIMAP spa Via Invalidi del Lavoro 1 37059 S Maria di Zevio Verona Italy Tel 39 045 6060411 Fax 39 045 6060417 E mail fimap fimap com www fimap com...