CONNECTION TO THE ELECTRICITY GRID
DANGER:
•
To reduce the risk of fire, electric shocks or injury, please read and comply with all the safety
instructions and warnings. This machine has been designed to be safe when it is used for
cleaning in the manner specified. If damage to electrical or mechanical components is found,
the machine must be repaired at the relative authorised service centre before use, in order to
prevent further damage to the machine or physical injury to the user.
• Before connecting the machine to the electric socket, make sure the electrical information on
the serial number plate corresponds to that of the mains supply.
The machine must only be
powered with alternating current and with a voltage equal to that shown on the serial
number plate
.
• The power supply cable outlet must have an earth connection in compliance with the
regulatory standards.
• If the machine packaging contains the cable to connect to the mains supply, it should only be
used for the above-mentioned machine.
• Before using, check for any damage on the connection cable and on the power plug. If the
cable is damaged, immediately contact a technician for restoring normal functioning.
• Connect the machine only to an electrical connection installed by an electrical installer in
conformity with IEC 60364-1.
• Never touch the power plug with wet hands.
• Make sure that the cable to the mains or the extension cable have not been damaged by
having been walked on, crushed, pulled or the like. Protect the cable from heat and from
contact with oils or sharp edges.
• Regularly check that the cable connecting to the mains is not damaged, for example with
signs of ageing or cracks. If the cable is damaged it should be replaced before using the
machine again.
• Protection against splashes of water and the mechanical strength need to be ensured also
after any replacement of the joints of the power cable or the extension cable.
ATTENTION:
• The procedure causes a short-term reduction in voltage.
• In unfavourable grid conditions the other appliances could be damaged.
•
This damage could occur if the grid impedance is less than 0.15Ω.
EXTENSION CABLES
CAUTION:
Only use the materials expressly recommended by
a service technician as cable extensions (contact an
authorised retailer) or else high quality models. When
using an extension, respect its minimum cross-section.
CABLE LENGTH
CABLE SECTION
<16A
<25A
Up to 20m
1.5mm
2
2.5mm
2
From 20m to 50m
2.5mm
2
4.0mm
2