WEEKLY MAINTENANCE
1.
CLEANING THE RECOVERY TANK
The careful cleaning of the recovery tank guarantees a longer appliance life span. Proceed as follows to clean the recovery tank:
1.
Take the device to the dedicated maintenance area.
2.
Take all necessary steps to ensure that the device is in a safe condition (see “
MACHINE SAFETY
”).
3.
Grip the handle (1) on the rear left side of the recovery tank (work direction) and turn the recovery tank until it reaches the work position.
4.
Secure the recovery tank with the hinge (2).
5.
Remove the recovery tank's drainage hose (3) from the clamps, located at the rear of the appliance; unscrew the cap and place it on the ground.
6.
Grip the handle (4) on the front side of the vacuum cap, rotate the vacuum cap until the hook (5) is secured to the recovery tank's prop (6).
7.
Rinse the inside with a jet of water, if necessary use a spatula to remove the sludge that has accumulated at the bottom of the tank.
8.
Repeat the operations in reverse order to reassemble all the parts.
WARNING: You are advised to always wear protective gloves, to avoid the risk of serious injury to your hands.
WARNING: The place this operation is carried out should comply with current environmental protection regulations.
2.
CLEANING THE SOLUTION TANK
The careful cleaning of the solution tank guarantees a longer appliance life span. Proceed as follows to clean the solution tank:
1.
Take the device to the dedicated maintenance area.
2.
Take all necessary steps to ensure that the device is in a safe condition (see “
MACHINE SAFETY
”)
3.
Grip the handle (1) on the rear left side of the recovery tank (work direction) and turn the recovery tank until it reaches the work position.
4.
Secure the recovery tank with the hinge (2).
5.
Check that the detergent solution tap is off; rotate the lever (3) on the rear of the appliance to the right (work direction).
6.
Loosen the solution tank cap (4) and clean it with clean running water; where needed, remove any impurities from it.
7.
Remove the filling cap (5) and the filter (6) on the front of the appliance. Clean the filter (6) with a jet of water and remove any dirt.
8.
Rinse the inside of the solution tank with a jet of water.
9.
Repeat the operations in reverse order to reassemble all the parts.
WARNING: You are advised to always wear protective gloves, to avoid the risk of serious injury to your hands.
WARNING: The place this operation is carried out should comply with current environmental protection regulations.
Page 27