VEGETABLE SLICER TV4000
Table 6:
Operating malfunctions
Problem
Causes
Solutions
The equipment does not start.
Main switch off.
Turn on main switch.
No mains power.
Contact your dealer or
authorised service centre.
The presser was not lowered.
Lower the presser.
The basket was not correctly
inserted.
Check correct basket insertion.
Fuse burnt-out.
Contact customer service.
The tool rotation direction is
incorrect.
Appliance power phase wires
are incorrectly connected.
Have an expert technician invert
power wires.
Summary of Contents for TAC
Page 4: ... 2 Lingua Italiana IT ...
Page 26: ......
Page 28: ... 2 English language GB ...
Page 50: ......
Page 52: ... 2 Langue française FR ...
Page 74: ......
Page 76: ... 2 Deutsche Sprache DE ...
Page 98: ......
Page 100: ... 2 Idioma español ES ...
Page 122: ......
Page 124: ... 2 Língua portuguesa PT ...
Page 146: ......
Page 148: ... 2 Русский язык PY ...
Page 170: ......
Page 172: ...IDM 34605501000 pdf SCHEMA ELETTRICO ELECTRIC DIAGRAM TV2000R 1 Phase ...
Page 173: ...SCHEMA ELETTRICO ELECTRIC DIAGRAM TV2000R 3 Phase IDM 34605501100 pdf ...
Page 174: ...SCHEMA ELETTRICO ELECTRIC DIAGRAM TV2500 IDM 34605501400 pdf ...
Page 175: ...SCHEMA ELETTRICO ELECTRIC DIAGRAM TV3000 1 Phase IDM 34605501200 pdf ...
Page 176: ...SCHEMA ELETTRICO ELECTRIC DIAGRAM TV3000 3 Phase IDM 34605501300 pdf ...
Page 177: ...SCHEMA ELETTRICO ELECTRIC DIAGRAM TV4000 1 Phase IDM 34605502100 pdf ...
Page 178: ...SCHEMA ELETTRICO ELECTRIC DIAGRAM TV4000 3 Phase IDM 34605502200 pdf ...
Page 179: ...SCHEMA ELETTRICO ELECTRIC DIAGRAM TAS TAC 1 Phase IDM 34605501700 pdf ...
Page 180: ...SCHEMA ELETTRICO ELECTRIC DIAGRAM TAS TAC 3 Phase IDM 34605501800 pdf ...
Page 186: ......
Page 187: ......
Page 189: ......
Page 190: ......