background image

Page 5 

 

IMPORTANT: 

Remove tank lid and be sure the tank is clean and free of any foreign  

material. Rinse tank out of any tank residue before filling with water to test. Make 

sure all hose clamps are tight.

 

 

Testing the Sprayer 

NOTE: 

It is VERY important for you to test your sprayer with plain water before actual spraying is  

attempted. This will enable you to check the sprayer for leaks without the possibility of losing 

any expensive chemicals. 

  

Fill the tank about 1/2 full with plain water and drive to the starting place for spraying.  

 

When you are ready to spray, open the boom valve to the “on” position (see boom valve open). This will 

start solution spraying from the tips of the boom. The pressure will decrease slightly when the boom is 

spraying.  

 

Read the operating instructions and initially begin spraying by opening the boom line valve This will  

enable the air in the line to be eliminated (purged) through all the tips, while building pressure. When  

everything tests all right, add the desired chemicals to the mixture and water combination and start your 

spraying operation. 

Conditions of weather and terrain must be considered when setting the sprayer. Do not spray on windy 

days.  

Protective clothing must be worn in some cases. 

 

Be sure to read the chemical label(s) before application! 

 

Operation 

The pumping system draws solution from the tank, through the strainer and to the pump. The pump forces the solution under pressure to the handgun 

or boom nozzles. 

 

Connect the lead wire to a fully charged 12 volt battery. You may use either a stand-alone battery or the battery on your towing vehicle. Connect to the 

positive (red) terminal first, then connect to the negative (black) terminal. Then connect the end of the lead wire to the end of the pump. When discon-

necting, disconnect the end of the pump wire from the lead wire, then disconnect the negative (black) connection and finally the positive (red) connec-

tion. The lead wire has an On/Off switch to activate the pump. “-” is on and “O” is off. 

 

Fill the tank part way with water and then add the desired amount of chemical to be sprayed. Finish filling tank to proper level. Turn the pump on and 

by depressing the “-” side of the rocker switch. The pump is equipped with a pressure switch that is pre-set at the factory to shut the pump off when all 

discharges are closed. 

 

The pump will turn back on when one of the following actions occurs: 

 

Handgun lever is squeezed to spray the handgun. 

 

Boom valve is opened to broadcast spray with the boom. 

Maintenance During/After Spraying 

Periodically check the strainer and clean the screen on your intake line. 

 

Proper care and maintenance will prolong the life of your sprayer. 

 

After use, drain the tank and store or dispose of chemical properly. Fill the sprayer half way with clean water. Start the pump and allow the water to 

pump through the entire plumbing system and nozzles. Drain and then refill half full, add the recommended amount of a good quality tank cleaner, 

such as FIMCO Tank Neutralizer and Cleaner. (If no tank cleaner is available, you may substitute dish soap for this step, about 1-2 oz. per gallon).  

Turn pump on and circulate through system for 15 minutes and then spray out through boom and handgun nozzles. Refill sprayer half way with clean 

water and repeat. Follow the chemical manufacturer’s disposal instructions of all wash or rinsing water.  

If boom or handgun nozzles need cleaning, remove them from the sprayer and soak in warm soapy water. Clean with a soft bristled brush or toothpick 

if necessary. Never use a metal object. Even the slightest damage can change the flow rate and spray distribution. Water rinse and dry the tips before 

storing. 

 

WARNING: 

Some chemicals will damage the pump valves if allowed to soak untreated for a length of time! ALWAYS flush the pump as 

instructed after each  use. DO NOT allow chemicals to sit in the pump for extended times of idleness. Follow the chemical manufacturer’s 

instructions on disposal of all waste water from the sprayer.

 

 

Winter Storage 

Prepare the sprayer for end-of-season storage by running RV antifreeze through the system. This will keep internal parts lubricated, protect against 

corrosion and keep the unit from freezing. 

Note: RV antifreeze is non-toxic and biodegradable and generally safer for the environment than automotive 

antifreeze.

 

Before storing your sprayer for winter or long term storage, thoroughly clean and drain it as much as possible. Then pour enough pink RV antifreeze 

into the tank so that when the pump is turned on you can pump the antifreeze throughout the entire plumbing system. Make sure to operate the boom 

and handgun until you see pink fluid spraying from the nozzles. Leave any remaining antifreeze in the tank. Before your next usage, rinse the  

antifreeze from the sprayer with clean water. 

It is nearly impossible to drain all of the water from the sprayer and any trapped water can freeze in cold weather and damage parts of the sprayer. 

Pumping the antifreeze through the system will displace the water and help prevent this damage. 

 

Removing from storage: drain the antifreeze. Fill the tank with fresh water and run through the system. Dispose of antifreeze and flush water properly. 

Valves Closed

 

Boom Valve Open

 

Summary of Contents for 15-2N-TRL-GS

Page 1: ...OWNER S MANUAL BEFORE RETURNING THIS PRODUCT FOR ANY REASON PLEASE CALL 1 800 831 0027 MONDAY FRIDAY 8 00 AM TO 5 00 PM CST If you should have a question or experience a problem with your Fimco Industries Product Visit our website www fimcoindustries com or call the Toll free number above Our technical support representatives will be happy to help you In most cases a customer service rep can resol...

Page 2: ...m Assembly Tires Wheels Contents of your sprayer s carton 15 2N TRL GS Owner s Manual Tank Lid Lanyard Tank Pre Assembly Axle Kit Contents of Parts Bolt Bag Entry Level Spray Wand 15 Hose Trailer Tongue Trailer Boom Mount ...

Page 3: ...ag Place on top and bottom of tongue and bolt together as shown in Step 2 Tighten the bolts and nuts securely Remove the axle cotter pins and 2 wheels from the carton Slide the axle through the hole in one side of the axle spacer and through the corre sponding hole on the other side Now slide a wheel over the axle and up against the axle spacer Make sure the valve stems of the wheels are facing ou...

Page 4: ...pping the spray wand hose from around the tank may be difficult The Sprayer should now be ready for use Screw the lid onto the tank if not already done Locate the 2 clips and 2 phillips head machine screws from the parts bag A phillips head screwdriver is required for this step Place a screw through the hole in the clip and bring it up to the tank where the embossments for the clips are located on...

Page 5: ...g After Spraying Periodically check the strainer and clean the screen on your intake line Proper care and maintenance will prolong the life of your sprayer After use drain the tank and store or dispose of chemical properly Fill the sprayer half way with clean water Start the pump and allow the water to pump through the entire plumbing system and nozzles Drain and then refill half full add the reco...

Page 6: ...ime Check for air leaks in supply line Check for debris in the check valve assembly Check for defective check valve Check for clogged strainer filter Check for cracks in the pump housing Check for empty product supply Low Pressure Low Flow Check for leaks in the discharge line Check for restriction in the discharge line Check for debris in nozzle orifice Check for clogged strainer Check for proper...

Page 7: ...ed If it still doesn t run try bypassing the switch in the lead wire or using another lead wire Even if a tester shows power to the pressure switch it still could be the switch in the wire that is causing the problem If still not responsive use a voltmeter or electrical tester to make sure you are getting power to the head of the pump as it could possibly be something in one of the wires or even t...

Page 8: ...Page 8 Exploded View Parts List 15 2N TRL GS 5303198 Y Valve Detail ...

Page 9: ... critical factor is to achieve a minimum 30 overlap Excellent spray distribution for uniform coverage along the boom Nozzle design incorporates a pre orifice to produce larger droplets for less drift 2 Nozzle Boom Assembly Exploded View Parts List For the safest and most efficient chemical application you will need to calibrate your sprayer using the tip and speed charts Once you have deter mined ...

Page 10: ...obtain warranty service under this Limited Warranty you must 1 provide written notice to Fimco Ind of the defect during the Warranty Period and within thirty 30 days after the defect becomes apparent or the repair becomes necessary at the following address Fimco Ind 1000 Fimco Lane North Sioux City SD 57049 and 2 make the Equipment available to Fimco Ind or an authorized dealer within a reasonable...

Reviews: