Page 1: ...OWNER S MANUAL BEFORE RETURNING THIS PRODUCT FOR ANY REASON PLEASE CALL 1 800 831 0027 MONDAY FRIDAY 8 00 AM TO 5 00 PM CST If you should have a question or experience a problem with your Fimco Industries Product Visit our website www fimcoindustries com or call the Toll free number above Our technical support representatives will be happy to help you In most cases a customer service rep can resol...

Page 2: ...m Assembly Tires Wheels Contents of your sprayer s carton 15 2N TRL GS Owner s Manual Tank Lid Lanyard Tank Pre Assembly Axle Kit Contents of Parts Bolt Bag Entry Level Spray Wand 15 Hose Trailer Tongue Trailer Boom Mount ...

Page 3: ...ag Place on top and bottom of tongue and bolt together as shown in Step 2 Tighten the bolts and nuts securely Remove the axle cotter pins and 2 wheels from the carton Slide the axle through the hole in one side of the axle spacer and through the corre sponding hole on the other side Now slide a wheel over the axle and up against the axle spacer Make sure the valve stems of the wheels are facing ou...

Page 4: ...pping the spray wand hose from around the tank may be difficult The Sprayer should now be ready for use Screw the lid onto the tank if not already done Locate the 2 clips and 2 phillips head machine screws from the parts bag A phillips head screwdriver is required for this step Place a screw through the hole in the clip and bring it up to the tank where the embossments for the clips are located on...

Page 5: ...g After Spraying Periodically check the strainer and clean the screen on your intake line Proper care and maintenance will prolong the life of your sprayer After use drain the tank and store or dispose of chemical properly Fill the sprayer half way with clean water Start the pump and allow the water to pump through the entire plumbing system and nozzles Drain and then refill half full add the reco...

Page 6: ...ime Check for air leaks in supply line Check for debris in the check valve assembly Check for defective check valve Check for clogged strainer filter Check for cracks in the pump housing Check for empty product supply Low Pressure Low Flow Check for leaks in the discharge line Check for restriction in the discharge line Check for debris in nozzle orifice Check for clogged strainer Check for proper...

Page 7: ...ed If it still doesn t run try bypassing the switch in the lead wire or using another lead wire Even if a tester shows power to the pressure switch it still could be the switch in the wire that is causing the problem If still not responsive use a voltmeter or electrical tester to make sure you are getting power to the head of the pump as it could possibly be something in one of the wires or even t...

Page 8: ...Page 8 Exploded View Parts List 15 2N TRL GS 5303198 Y Valve Detail ...

Page 9: ... critical factor is to achieve a minimum 30 overlap Excellent spray distribution for uniform coverage along the boom Nozzle design incorporates a pre orifice to produce larger droplets for less drift 2 Nozzle Boom Assembly Exploded View Parts List For the safest and most efficient chemical application you will need to calibrate your sprayer using the tip and speed charts Once you have deter mined ...

Page 10: ...obtain warranty service under this Limited Warranty you must 1 provide written notice to Fimco Ind of the defect during the Warranty Period and within thirty 30 days after the defect becomes apparent or the repair becomes necessary at the following address Fimco Ind 1000 Fimco Lane North Sioux City SD 57049 and 2 make the Equipment available to Fimco Ind or an authorized dealer within a reasonable...