Page 5 

 

Manifold Valves CLOSED 

IMPORTANT: Remove tank lid and be sure the tank is clean and free 

of any foreign material. Rinse tank out of any tank residue before fill-

ing with water to test. 

 

Testing the Sprayer 

NOTE: 

It is VERY important for you to test your sprayer with plain water before actu-

al spraying is attempted. This will enable you to check the sprayer for leaks 

without the possibility of losing any expensive chemicals. 

  

Fill the tank about 1/2 full with plain water and drive to the starting place for spraying.  

 

When you are ready to spray, turn the boom valve to the “on” position (Detail A). This will start 

solution spraying from the tips of the boom. The pressure will decrease slightly when the 

boom is spraying.  

Adjust the pressure by turning the “ON/OFF” valve lever on the bypass line valve (Detail B). 

Make sure your pattern is sufficient. You may down-pressure the system by ‘bypassing’ solu-

tion back into the tank. This is achieved by opening the bypass valve. Regulating pressure is 

done in this manner. 

 

Read the operating instructions and initially begin spraying by closing the ‘Pressure Adjust’ 

valve and opening the boom line valve (Detail A). This will enable the air in the line to be elimi-

nated (purged) through all the tips, while building pressure. When everything tests all right (no 

leaks and good pressure), add the desired chemicals to the mixture and water combination 

and start your spraying operation. Adjust the pressure and spray as you did in the testing 

procedure. 

Conditions of weather and terrain must be considered when setting the sprayer. Do not spray 

on windy days. Protective clothing must be worn in some cases. 

 

Be sure to read the chemical label(s) before application! 

 

Operation 

The pumping system draws solution from the tank, through the strainer and to the pump. The 

pump forces the solution under pressure to the handgun or boom nozzles. 

 

Connect the lead wire to a fully charged 12 volt battery. You may use either a stand-alone 

battery or the battery on your towing vehicle. Connect to the positive (red) terminal first, then 

connect to the negative (black) terminal. Then connect the end of the lead wire to the end of 

the pump. When disconnecting, disconnect the end of the pump wire from the lead wire, then 

disconnect the negative (black) connection and finally the positive (red) connection. The lead 

wire has an On/Off switch to activate the pump. “-” is on and “O” is off. 

 

Fill the tank part way with water and then add the desired amount of chemical to be sprayed. 

Finish filling tank to proper level. Turn the pump on and by depressing the “-” side of the rock-

er switch. The pump is equipped with a pressure switch that is pre-set at the factory to shut 

the pump off when all discharges are closed. 

 

The pump will turn back on when one of the following actions occurs: 

 

Handgun lever is squeezed to spray the handgun. 

 

Boom valve is opened to broadcast spray with the boom. 

 

Bypass valve is opened to re-circulate solution back into the tank. 

 

When spraying with either the boom or the handgun, pressure may be reduced by slowly 

opening the bypass valve until desired pressure is achieved. Opening the valve decreases 

pressure, closing the valve increases pressure. When spraying with the boom, the proper 

method to set the pressure is to open the boom valve completely and if a lower pressure is desired, then slowly open the bypass valve until that pres-

sure is obtained. 

 

For the safest and most efficient chemical application, you will need to calibrate your sprayer using the tip and speed charts. Once you have deter-

mined the proper speed and pressure settings, you will need to consult your chemical label for the amount of chemical to be added to the tank. Read 

the entire label. Use only according to label directions. 

 

Calibration 

Chemical labels may show application rates in gallons per acre, gallons per 1000 square feet or gallons per 100 square feet. You will note that the tip 

chart shows 3 of these rating systems. Once you know how much you are going to spray, then determine (from the tip chart) the spraying pressure 

(PSI), and the spraying speed (MPH). 

 

Determining the proper speed of the pulling vehicle can be done by marking off 100, 200 & 300 feet. The speed chart indicates the number of seconds 

it takes to travel the distances. Set the throttle and with a running start, travel the distances. Adjust the throttle until you travel the distances in the 

number of seconds indicated by the speed chart. Once you have reached the throttle setting needed, mark the throttle location so you can stop and go 

again, returning to the same speed. 

 

Add water and proper amount of chemical to the tank and drive to the starting place for spraying. 

Detail A 

Detail B 

Summary of Contents for 5301439

Page 1: ...s with an On Off shut off valve located at the inlet location of the tank towards the underside See Detail A You must make sure the valve is in the open position before using your sprayer Detail A OWNER S MANUAL BEFORE RETURNING THIS PRODUCT FOR ANY REASON PLEASE CALL 1 800 831 0027 MONDAY FRIDAY 8 00 AM TO 5 00 PM CST If you should have a question or experience a problem with your Fimco Industrie...

Page 2: ...our sprayer s carton LG 1500 304 Contents of Parts Bag 5278316 Tank Lid Lanyard 5058188 Tank Frame Pre Assembly 2 Nozzle Boom Assembly 5277774 2 Tires Wheels 5021092 Owner s Manual 15 20 Gallon Trailer Bracket Kit 5277727 ...

Page 3: ...he axle and 2 wheels from the carton Remove the 2 wheel spacers and 2 cotter pins from the parts bag Slide the axle through the hole in one side of the frame and through the corresponding hole on the other side of the frame You may need to maneuver squeeze the frame slightly while doing this to get the axle through both holes Center the axle about the frame as best as possible Slide a wheel spacer...

Page 4: ...o the tank Do not over tighten These clips are where the spray gun is secured to the tank while not in use NOTE The spray gun should already be attached to the 15 foot hose prior to assembly The Sprayer should now be ready for use Assembly Procedure LG 1500 304 Remove the 2 nozzle boom assembly from the carton Using 2 bolts and 2 whiz nuts bolt the boom to the upright boom mounting brackets There ...

Page 5: ...en disconnect the negative black connection and finally the positive red connection The lead wire has an On Off switch to activate the pump is on and O is off Fill the tank part way with water and then add the desired amount of chemical to be sprayed Finish filling tank to proper level Turn the pump on and by depressing the side of the rock er switch The pump is equipped with a pressure switch tha...

Page 6: ...me chemicals will damage the pump valves if allowed to soak untreated for a length of time ALWAYS flush the pump as instructed after each use DO NOT allow chemicals to sit in the pump for extended times of idleness Follow the chemical manufacturer s instructions on disposal of all waste water from the sprayer Winter Storage Prepare the sprayer for end of season storage by running RV antifreeze thr...

Page 7: ...alve Check for clogged strainer filter Check for cracks in the pump housing Check for empty product supply Low Pressure Low Flow Check for leaks in the discharge line Check for restriction in the discharge line Check for debris in nozzle orifice Check for clogged strainer Check for proper voltage try another 12 volt battery Pulsating flow surging Low flow may cause pump to surge Spray wand is adju...

Page 8: ...an hour or so in the hot soapy solution and replace in the pump and reassemble the pump Most times this will restore most if not all of the prime of a pump If you re still having issues with pressure after this step it would be recommended to replace this part Checking the Pressure Switch If your motor is not running and you ve checked the following for loose wiring connections fuse the switch on ...

Page 9: ...Page 9 Manifold Detail Exploded View Parts List LG 1500 304 5301439 Intake Detail ...

Page 10: ...ggested Minimum Spray Height 18 20 above what is being sprayed to plant not ground Optimum Spray Height 39 Wide angle spray nozzle height is influenced by nozzle orientation The criti cal factor is to achieve a minimum 30 overlap Excellent spray distribution for uniform coverage along the boom Nozzle design incorporates a pre orifice to pro duce larger droplets for less drift ...

Page 11: ... filter screen Start your pump and before it shuts off reach down and shut the valve to the Closed position lever is perpendicular to the flow of fluid then shut off your pump Unscrew the knurled nut from the shut off valve leaving the valve connected to the tank Swing swivel the intake assembly towards you Look in the nut you JUST unscrewed There is a screen washer there Remove the screen and cle...

Page 12: ...obtain warranty service under this Limited Warranty you must 1 provide written notice to Fimco Ind of the defect during the Warranty Period and within thirty 30 days after the defect becomes apparent or the repair becomes necessary at the following address Fimco Ind 1000 Fimco Lane North Sioux City SD 57049 and 2 make the Equipment available to Fimco Ind or an authorized dealer within a reasonable...

Reviews: