DO 

 

Clean and rinse your pump after each use with Fimco Tank 
Neutralizer 

 

Winterize your pump or sprayer by rinsing, draining and  
running RV Antifreeze through it before storing for the winter. 

 

Use clean water for your spray mixture 

 

Store inside a building when not in use. 

DON’T 

 

Use to pump bleach. 

 

Use to pump petroleum products such as diesel fuel,    
gasoline or kerosene 

 

Leave your pump sit with spray mixture in it for extended 
periods 

 

Use dirty or unfiltered water for spraying 

Troubleshooting the Pump: 

Motor does not run: 

 

Check for loose wiring connection(s). 

 

Make sure the 'ON/OFF' switch in the lead wire assembly 

is in the 'ON' position. "I" is the 'ON' position and 'O' is 

the 'OFF' position. 

 

Check for defective pressure switch. Make sure you are 

connected to a good  12 volt power source. Make sure 

any on/off switches are in the 'on' position.  Remove the 

cap to the pressure switch. Pull both red wires off of their 
terminals, and touch the two ends together. If your pump 

runs when you do this, your   pressure switch will need to 

be replaced. 

 

Check the fuse. 

 

Check for low voltage at the power supply. 

 

 

Pump does not prime: 

 

Check for air leaks in supply line. 

 

Check for debris in the check valve assembly. 

 

Check for defective check valve. 

 

Check for clogged strainer/filter. 

 

Check for cracks in the pump housing. 

 

Check for empty product supply. 

 

Low Pressure/Low Flow: 

 

Check for leaks in the discharge line. 

 

Check for restriction in the discharge line. 

 

Check for debris in nozzle orifice. 

 

Check for clogged strainer. 

 

Check for proper voltage—try another 12-volt battery. 

Pulsating flow (surging): 

 

Low flow may cause pump to surge. 

 

Spray wand is adjusted for a small or fine spray pattern. 

 

Slightly open bypass (if applicable) to overcome. 

 

If needed, pressure switch may need to be adjusted—

adjust a quarter turn at a time clockwise until surging 

stops. 

 

Check for defective pressure switch. 

 

Check for leaks in the discharge line. 

 

Check for restriction in the discharge line. 

 

Check for debris in nozzle orifice. 

 

Discharge hose may be too long. 

 

Check for clogged strainer. 

 
Motor continues to run after discharge is shut off: 

 

Check for empty product supply. 

 

Check for open bypass valve. (if equipped) 

 

Check for low voltage. 

 

Check for leak in discharge line. 

 

Check for defective pressure switch. 

 

System has leaks. 

 

Fuse blows: 

 

Excessive voltage. 

 

Improper adjustment of pressure switch. 

 

Damaged or defective wiring harness. 

 

Defective pressure switch. 

Replacement Pump:  5151087 

 

 

 

 

 

 

Includes:   

 

 

 

 

 

 

 

1/2” MNPT Port Kit Fitting  

 

 

 

 

 

 

 

 

#5168832 

 

 

 

 

 

 

 

1/2” Hose Barb Port Kit Fitting  

 

 

 

 

 

 

 

 

#5168833 

 

 

 

 

 

 

 

3/8” Hose Barb Port Kit Fitting  

 

 

 

 

 

 

 

 

#5168836 

Pump Model:  5281371 

2.4 GPM, 60 PSI 

Available Replacement Parts 

Summary of Contents for 5302186

Page 1: ...l throw OWNER S MANUAL BEFORE RETURNING THIS PRODUCT FOR ANY REASON PLEASE CALL 1 800 831 0027 MONDAY FRIDAY 8 00 AM TO 5 00 PM CST If you should have a question or experience a problem with your Fimco Industries Product Visit our website www fimcoindustries com or call the Toll free number above Our technical support representatives will be happy to help you In most cases a customer service rep c...

Page 2: ... Fill the sprayer half way with clean water Start the pump and allow the water to pump through the entire plumbing system and nozzle Drain and then refill half full add the recommended amount of a good quality tank cleaner such as FIMCO Tank Neutralizer and Cleaner If no tank cleaner is available you may substitute dish soap for this step about 1 2 oz per gallon Turn pump on and circulate through ...

Page 3: ... defective check valve Check for clogged strainer filter Check for cracks in the pump housing Check for empty product supply Low Pressure Low Flow Check for leaks in the discharge line Check for restriction in the discharge line Check for debris in nozzle orifice Check for clogged strainer Check for proper voltage try another 12 volt battery Pulsating flow surging Low flow may cause pump to surge ...

Page 4: ...an hour or so in the hot soapy solution and replace in the pump and reassemble the pump Most times this will restore most if not all of the prime of a pump If you re still having issues with pressure after this step it would be recommended to replace this part Checking the Pressure Switch If your motor is not running and you ve checked the following for loose wiring connections fuse the switch on ...

Page 5: ...Page 5 Exploded View Parts List LG 40 DLX 5302186 ...

Page 6: ...btain warranty service under this Limited Warranty you must 1 provide written notice to Fimco Ind of the defect during the Warranty Period and within thirty 30 days after the defect becomes apparent or the repair becomes necessary at the following address Fimco Ind 1000 Fimco Lane North Sioux City SD 57049 and 2 make the Equipment available to Fimco Ind or an authorized dealer within a reasonable ...

Reviews: