Step 3 

Assembly Procedure (ATV-25-700-QR) 

After  your  boom  mounting  brackets  are  secured  in 

place and the unit secured on your ATV, bolt the  

7-nozzle boom in place with (2)  Square U-Bolts and  

whiz nuts. 

 

A 1/2” socket or wrench is required for this step. 

 

This boom can be positioned as shown or in a few  

alternate positions.  

 

Try to maintain approximately 18-22 inches above the 

items being sprayed, for optimal coverage. This is con-

sidered  where  the  nozzles  will  mount,  at  the  end  of 

these brackets. 

With  the  boom  secured  to  the  boom  mounting  brack-

ets, the nozzle harness can now be attached. 

 

Attach the nozzle harness to the boom. Using the  

nozzle clamps, attach the nozzle harness to the boom 

as shown in DETAIL Clamp. 

Step 4 

DETAIL Clamp 

Summary of Contents for 5302320

Page 1: ...hould already be attached to the tank IMPORTANT REMINDER This sprayer comes with an On Off shut off valve located at the inlet location of the tank towards the underside See Detail A You must make sure the valve is in the open position before using your sprayer Detail A OWNER S MANUAL BEFORE RETURNING THIS PRODUCT FOR ANY REASON PLEASE CALL 1 800 831 0027 MONDAY FRIDAY 8 00 AM TO 5 00 PM CST If yo...

Page 2: ...carton ATV 25 700 QR 5302320 7 Nozzle Boom 5277780 7 Nozzle Harness 5277696 Nozzle Clamps Pkg of 7 5277730 Contents of Parts Bag 5278132 Tank Lid Lanyard 5058188 Contents of Bracket Kit 5278133 Tank Plumbing Pre Assembly Owner s Manual ...

Page 3: ... 4 flat head screws to secure it to the tank The tank will rest on the surface of the brack ets Make sure the brackets are parallel with each other before tightening down the bolts Do not over tighten After your tank brackets are securely attached turn the tank assembly over and position it so that the cam handles which extend beyond the back of the tank are facing you and just hanging over the ed...

Page 4: ...n be positioned as shown or in a few alternate positions Try to maintain approximately 18 22 inches above the items being sprayed for optimal coverage This is con sidered where the nozzles will mount at the end of these brackets With the boom secured to the boom mounting brack ets the nozzle harness can now be attached Attach the nozzle harness to the boom Using the nozzle clamps attach the nozzle...

Page 5: ...tall the pressure gauge Hand tighten securely DO NOT OVER TIGHTEN Detail B Screw the lid onto the tank Place the end of the lanyard through the tab in the tank This is so the lid can hang off the tank when filling rinsing the tank out Detail C Locate the 2 clips and 2 phillips head machine screws from the parts bag A phillips head screwdriver is required for this step Place a screw through the hol...

Page 6: ...n disconnect the negative black connection and finally the positive red connection The lead wire has an On Off switch to activate the pump is on and O is off Fill the tank part way with water and then add the desired amount of chemical to be sprayed Finish filling tank to proper level Turn the pump on and by depressing the side of the rock er switch The pump is equipped with a pressure switch that...

Page 7: ...orrosion and keep the unit from freezing Note RV antifreeze is non toxic and biodegradable and generally safer for the environment than automotive anti freeze Before storing your sprayer for winter or long term storage thoroughly clean and drain it as much as possible Then pour enough pink RV antifreeze into the tank so that when the pump is turned on you can pump the antifreeze throughout the ent...

Page 8: ... defective check valve Check for clogged strainer filter Check for cracks in the pump housing Check for empty product supply Low Pressure Low Flow Check for leaks in the discharge line Check for restriction in the discharge line Check for debris in nozzle orifice Check for clogged strainer Check for proper voltage try another 12 volt battery Pulsating flow surging Low flow may cause pump to surge ...

Page 9: ...e replaced If it still doesn t run try bypassing the switch in the lead wire or using another lead wire Even if a tester shows power to the pressure switch it still could be the switch in the wire that is causing the problem If still not responsive use a voltmeter or electrical tester to make sure you are getting power to the head of the pump as it could possibly be something in one of the wires o...

Page 10: ...Page 10 Exploded View Parts List ATV 25 700 QR 5302320 Manifold Detail 5281538 Intake Assembly 5281145 ...

Page 11: ...10 tips and 20 spacing Suggested Minimum Spray Height 16 18 above what is being sprayed to plant not ground Optimum Spray Height 20 110 wide tapered flat spray angle with air induction technology for better drift management Made of 2 piece UHMWPE polymer construction which provides excellent chemical resistance includ ing acids as well as exceptional wear life Compact size to prevent tip damage Ex...

Page 12: ...obtain warranty service under this Limited Warranty you must 1 provide written notice to Fimco Ind of the defect during the Warranty Period and within thirty 30 days after the defect becomes apparent or the repair becomes necessary at the following address Fimco Ind 1000 Fimco Lane North Sioux City SD 57049 and 2 make the Equipment available to Fimco Ind or an authorized dealer within a reasonable...