Manifold Valves CLOSED 

IMPORTANT: 

Remove tank lid and be sure the tank is clean and free of 

any foreign material. Rinse tank out of any tank residue before filling with 

water to test. 

 

Testing the Sprayer 

NOTE: 

It is VERY important for you to test your sprayer with plain water before actual 

spraying is attempted. This will enable you to check the sprayer for leaks without 

the possibility of losing any expensive chemicals. 

  

Fill the tank about 1/2 full with plain water and drive to the starting place for spraying.  

 

When you are ready to spray, turn the boom valve to the “on” position (Detail A). This will start 

solution spraying from the tips of the boom. The pressure will decrease slightly when the 

boom is spraying.  

Adjust the pressure by turning the “ON/OFF” valve lever on the bypass line valve (Detail B). 

Make sure your pattern is sufficient. You may down-pressure the system by ‘bypassing’ solu-

tion back into the tank. This is achieved by opening the bypass valve. Regulating pressure is 

done in this manner. 

 

Read the operating instructions and initially begin spraying by closing the ‘Pressure Adjust’ 

valve and opening the boom line valve (Detail A). This will enable the air in the line to be elimi-

nated (purged) through all the tips, while building pressure. When everything tests all right (no 

leaks and good pressure), add the desired chemicals to the mixture and water combination 

and start your spraying operation. Adjust the pressure and spray as you did in the testing 

procedure. 

Conditions of weather and terrain must be considered when setting the sprayer. Do not spray 

on windy days. Protective clothing must be worn in some cases. 

 

Be sure to read the chemical label(s) before application! 

 

Operation 

The pumping system draws solution from the tank, through the strainer and to the pump. The 

pump forces the solution under pressure to the handgun or boom nozzles. 

 

Connect the lead wire to a fully charged 12 volt battery. You may use either a stand-alone 

battery or the battery on your towing vehicle. Connect to the positive (red) terminal first, then 

connect to the negative (black) terminal. Then connect the end of the lead wire to the end of 

the pump. When disconnecting, disconnect the end of the pump wire from the lead wire, then 

disconnect the negative (black) connection and finally the positive (red) connection. The lead 

wire has an On/Off switch to activate the pump. “-” is on and “O” is off. 

 

Fill the tank part way with water and then add the desired amount of chemical to be sprayed. 

Finish filling tank to proper level. Turn the pump on and by depressing the “-” side of the rock-

er switch. The pump is equipped with a pressure switch that is pre-set at the factory to shut 

the pump off when all discharges are closed. 

 

The pump will turn back on when one of the following actions occurs: 

 

Handgun lever is squeezed to spray the handgun. 

 

Boom valve is opened to broadcast spray with the boom. 

 

Bypass valve is opened to re-circulate solution back into the tank. 

 

When spraying with either the boom or the handgun, pressure may be reduced by slowly 

opening the bypass valve until desired pressure is achieved. Opening the valve decreases 

pressure, closing the valve increases pressure. When spraying with the boom, the proper 

method to set the pressure is to open the boom valve completely and if a lower pressure is desired, then slowly open the bypass valve until that pres-

sure is obtained. 

 

For the safest and most efficient chemical application, you will need to calibrate your sprayer using the tip and speed charts. Once you have deter-

mined the proper speed and pressure settings, you will need to consult your chemical label for the amount of chemical to be added to the tank. Read 

the entire label. Use only according to label directions. 

 

Calibration 

Chemical labels may show application rates in gallons per acre, gallons per 1000 square feet or gallons per 100 square feet. You will note that the tip 

chart shows 2 of these rating systems. Once you know how much you are going to spray, then determine (from the tip chart) the spraying pressure 

(PSI), and the spraying speed (MPH). 

 

Determining the proper speed of the pulling vehicle can be done by marking off 100, 200 & 300 feet. The speed chart indicates the number of seconds 

it takes to travel the distances. Set the throttle and with a running start, travel the distances. Adjust the throttle until you travel the distances in the 

number of seconds indicated by the speed chart. Once you have reached the throttle setting needed, mark the throttle location so you can stop and go 

again, returning to the same speed. 

 

Add water and proper amount of chemical to the tank and drive to the starting place for spraying. 

Detail A 

Detail B 

Summary of Contents for 5302320

Page 1: ...hould already be attached to the tank IMPORTANT REMINDER This sprayer comes with an On Off shut off valve located at the inlet location of the tank towards the underside See Detail A You must make sure the valve is in the open position before using your sprayer Detail A OWNER S MANUAL BEFORE RETURNING THIS PRODUCT FOR ANY REASON PLEASE CALL 1 800 831 0027 MONDAY FRIDAY 8 00 AM TO 5 00 PM CST If yo...

Page 2: ...carton ATV 25 700 QR 5302320 7 Nozzle Boom 5277780 7 Nozzle Harness 5277696 Nozzle Clamps Pkg of 7 5277730 Contents of Parts Bag 5278132 Tank Lid Lanyard 5058188 Contents of Bracket Kit 5278133 Tank Plumbing Pre Assembly Owner s Manual ...

Page 3: ... 4 flat head screws to secure it to the tank The tank will rest on the surface of the brack ets Make sure the brackets are parallel with each other before tightening down the bolts Do not over tighten After your tank brackets are securely attached turn the tank assembly over and position it so that the cam handles which extend beyond the back of the tank are facing you and just hanging over the ed...

Page 4: ...n be positioned as shown or in a few alternate positions Try to maintain approximately 18 22 inches above the items being sprayed for optimal coverage This is con sidered where the nozzles will mount at the end of these brackets With the boom secured to the boom mounting brack ets the nozzle harness can now be attached Attach the nozzle harness to the boom Using the nozzle clamps attach the nozzle...

Page 5: ...tall the pressure gauge Hand tighten securely DO NOT OVER TIGHTEN Detail B Screw the lid onto the tank Place the end of the lanyard through the tab in the tank This is so the lid can hang off the tank when filling rinsing the tank out Detail C Locate the 2 clips and 2 phillips head machine screws from the parts bag A phillips head screwdriver is required for this step Place a screw through the hol...

Page 6: ...n disconnect the negative black connection and finally the positive red connection The lead wire has an On Off switch to activate the pump is on and O is off Fill the tank part way with water and then add the desired amount of chemical to be sprayed Finish filling tank to proper level Turn the pump on and by depressing the side of the rock er switch The pump is equipped with a pressure switch that...

Page 7: ...orrosion and keep the unit from freezing Note RV antifreeze is non toxic and biodegradable and generally safer for the environment than automotive anti freeze Before storing your sprayer for winter or long term storage thoroughly clean and drain it as much as possible Then pour enough pink RV antifreeze into the tank so that when the pump is turned on you can pump the antifreeze throughout the ent...

Page 8: ... defective check valve Check for clogged strainer filter Check for cracks in the pump housing Check for empty product supply Low Pressure Low Flow Check for leaks in the discharge line Check for restriction in the discharge line Check for debris in nozzle orifice Check for clogged strainer Check for proper voltage try another 12 volt battery Pulsating flow surging Low flow may cause pump to surge ...

Page 9: ...e replaced If it still doesn t run try bypassing the switch in the lead wire or using another lead wire Even if a tester shows power to the pressure switch it still could be the switch in the wire that is causing the problem If still not responsive use a voltmeter or electrical tester to make sure you are getting power to the head of the pump as it could possibly be something in one of the wires o...

Page 10: ...Page 10 Exploded View Parts List ATV 25 700 QR 5302320 Manifold Detail 5281538 Intake Assembly 5281145 ...

Page 11: ...10 tips and 20 spacing Suggested Minimum Spray Height 16 18 above what is being sprayed to plant not ground Optimum Spray Height 20 110 wide tapered flat spray angle with air induction technology for better drift management Made of 2 piece UHMWPE polymer construction which provides excellent chemical resistance includ ing acids as well as exceptional wear life Compact size to prevent tip damage Ex...

Page 12: ...obtain warranty service under this Limited Warranty you must 1 provide written notice to Fimco Ind of the defect during the Warranty Period and within thirty 30 days after the defect becomes apparent or the repair becomes necessary at the following address Fimco Ind 1000 Fimco Lane North Sioux City SD 57049 and 2 make the Equipment available to Fimco Ind or an authorized dealer within a reasonable...

Reviews: